V. Chapitre, Approche pour la détermination de la teneur en eau du bois par diffusion cohérente de rayons X

C. Aguilera, M. Ramos, and D. Et-salinas, VISUALIZACI??N INTERNA DE NUDOS EN ROLLIZOS DE MADERA DE PINUS RADIATA D. DON UTILIZANDO RAYOS-X, Maderas. Ciencia y tecnolog??a, vol.4, issue.2, pp.193-200, 2002.
DOI : 10.4067/S0718-221X2002000200010

. Amptek, XR-100CR X-ray detector. [Online] Available: http://www.amptek.com/xr100cr.html. I. Amptek, 2005.

S. Andersson, R. Serimaa, T. Paakkari, P. Sarampää, and E. Et-pesonen, Cristallinity of wood and the size of cellulose crystallites in Norway spruce (Picea abies), Journal of Wood Science, issue.49, pp.531-537, 2003.

S. Andersson, R. Serimaa, M. Torkkeli, T. Paakkari, and E. Et-saranpää, Microfibril angle of Norway spruce [Picea abies (L.) Karst.] compression wood: comparison of measuring techniques, Journal of Wood Science, vol.31, issue.2, pp.343-349, 2000.
DOI : 10.1007/BF00776394

E. Badel, Détermination des propriétés élastiques et du retrait d'un cerne annuel de chêne dans le plan transverse: Description de la morphologie, mesures des propriétés microscopiques et calculs d'homogénéisation, Thèse ENGREF, 1999.

H. Baillères, F. Davrieux, and F. Ham-pichavant, Near infrared analysis as a tool for rapid screening of some major wood characteristics in a eucalytus breeding program, Annals of Forest Science, issue.59, pp.479-490, 2002.

T. W. Bauters, D. A. Dicarlo, and T. S. Et-steenhuis, Rapid, quantitative tracking of fluid flow in soils with synchrotron x-rays, 2000.

D. Bentz and K. Et-hansen, Preliminary observations of water movement in cement pastes during curing using X-ray absorption, Cement and Concrete Research, vol.30, issue.7, pp.1157-1168, 2000.
DOI : 10.1016/S0008-8846(00)00273-8

J. Bouet and J. Et-humbert, Le bois; une énergie renouvelable, 2003.

. Themadocs, SCEREN Services Culture Editions Ressources pour l'Education Nationale

M. Bucki, Etude expérimentale et simulation numérique d'un procédé de séchage couplé vide et hautes féquences, 2004.

V. Bucur, Techniques for high resolution imaging of wood structure: a review, Measurement Science and Technology, vol.14, issue.12, pp.91-98, 2003.
DOI : 10.1088/0957-0233/14/12/R01

J. M. Cardoso, J. B. Simoes, T. Menezes, and C. M. Et-correia, CdZnTe spectra improvement through digital pulse amplitude correction using the linear sliding method, Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol.505, issue.1-2, 2001.
DOI : 10.1016/S0168-9002(03)01091-X

C. Carll and A. Et-ten-wolde, Accuracy of wood resistance sensors for measurement of humidity, Journal of Testing and Evaluation, vol.24, issue.3, pp.154-160, 1996.

C. A. Carlsson and G. A. Et-carlsson, Basic physics of X-ray imaging, 1996.

I. Cave and W. Et-robinson, Measuring microfibril angle distribution in the cell wall by means of x-ray diffraction, pp.94-107, 1997.

I. D. Cave, Theory of x-ray measurement of microfibril angle in wood. Part 1. The condition for reflection. X-ray diffraction by materials with fibre type symmetry, Wood Science and Technology, issue.31, pp.143-152, 1997.

I. D. Cave, Theory of X-ray measurement of microfibril angle in wood, Wood Science and Technology, vol.49, issue.4, pp.225-234, 1997.
DOI : 10.1007/BF00702610

S. J. Chang, External and internal defect detection to optimize cutting of hardwood logs and lumber, 1992.

S. J. Chang, J. R. Olson, and P. C. Wang, NMR imaging of internal features in wood, Forest Products Journal, vol.6, issue.39, pp.43-49, 1989.

D. Choffel, Classement automatique des bois de structure par capteurs micro-ondes, 1995.

M. C. Clarijs, V. R. Bom, Z. I. Kolar, C. W. Van-eijk, J. Frieling et al., Optimized x-ray spectra for multiphase-flow measurements, 1999.

D. J. Cown and B. C. Clement, A wood densitometer using direct scanning with X-rays, Wood Science and Technology, vol.20, issue.3, 1983.
DOI : 10.1007/BF00369126

G. Dai and K. Ahmet, Long-term monitoring of timber moisture content below the fiber saturation point using wood resistance sensors, Forest Products Journal, vol.5, issue.51, pp.52-58, 2001.

J. R. Davis, Moisture content in drying wood using direct scanning gamma-ray densitometry, Wood and Fiber Science, vol.25, issue.2, pp.153-162, 1993.

J. M. Dinten, C. Robert-coutant, and M. Et-darboux, Dual-energy x-ray absortiometry using a 2D digital radiography detector, 2001.

F. Divos, S. Szegedi, and P. Et-raics, Lokale Dichtemessung des Holzes mit Hilfe der ??-Reflektionstechnik, Holz als Roh- und Werkstoff, vol.12, issue.4, pp.279-281, 1996.
DOI : 10.1007/s001070050183

L. A. Donalson, The use of pit apertures as windows to measure microfibril angle in chemical pulp fibers, Wood and Fiber Science, vol.23, issue.2, pp.291-295, 1991.

P. Duvauchelle, G. Peix, and D. Et-babot, Effective atomic number in the Raleigh to Compton scattering ratio. Nuclear Instruments an Methods in, Physics Research B, vol.155, pp.221-228, 1999.

R. Evans, S. Stuart, and J. Van-der-touw, Microfibril angle scanning of increment cores by x-ray diffractometry, Appita Journal, vol.49, issue.6, pp.411-414, 1996.

R. Evans, Rapid scanning of microfibril angle in increment cores by x-ray diffractometry, pp.116-139, 1997.

R. Evans, A variance approach to the x-ray diffractometric estimation of microfibril angle in wood, Appita Journal, vol.52, issue.4, pp.283-294, 1999.

R. Evans, M. Hughes, and D. Et-menz, Microfibril angle variation by scanning X-ray diffractometry, Appita Journal, vol.52, issue.5, pp.363-637, 1999.

R. Evans, Art, Science and Informatics -Visualisation of large, complex data sets in high-speed measurement of the microstructure of wood. The Burgess-Lane Memorial Lectureship in Forestry, The University of Bristish Columbia, 2002.

J. P. Evans, Stereoscopic imaging using folded linear dual-energy x-ray detectors, Measurement Science and Technology, vol.13, issue.9, pp.1388-1397, 2002.
DOI : 10.1088/0957-0233/13/9/303

K. Fung and W. Et-gilboy, "Anode heel effect" on patient dose in lumbar spine radiography., The British Journal of Radiology, vol.73, issue.869, pp.531-536, 2000.
DOI : 10.1259/bjr.73.869.10884750

C. P. Hansen, Application of the pilodyn in forest tree improvement. DFSC Series of Technical Notes. TN55, 2000.

K. Hansen, L. Genward, and K. Singh, Dual-energy absortiometry for the simultaneous determination of density and moisture content in porous structural materials, Proceeding of the 5th symposium on Building Physics, 1999.

W. Healy, Moisture sensor technology -A summary of techniques for measuring moisture levels in building envelopes, ASHRAE Transactions, vol.109, issue.1, pp.232-242, 2003.

L. Heger, M. L. Parker, and R. W. Kennedy, X-ray densitometry: A technique and an example of application, Wood Science, vol.7, issue.2, pp.140-148, 1974.

T. Higuchi, Biochemistry and molecular biology of wood, 1997.
DOI : 10.1007/978-3-642-60469-0

M. Hoag and M. D. Et-mckimmy, Direct scanning x-ray densitometry of thin wood sections, Forest Products Journal, vol.1, issue.38, pp.23-26, 1988.

J. Hu and P. Et-stroeven, X-ray absorption study of drying cement paste and mortar, Cement and Concrete Research, vol.33, issue.3, pp.397-403, 2003.
DOI : 10.1016/S0008-8846(02)00972-9

C. L. Huang, N. P. Kutscha, G. J. Leaf, and R. A. Et-megraw, Comparison of microfibril angle measurement techniques. Microfibril angle in wood, B. G. Butterfield, pp.177-205, 1997.

J. H. Hubbell and S. M. Et-seltzer, Tables of X-Ray Mass Attenuation Coefficients and Mass Energy-Absorption Coefficients (version 1.4). [Online] Available: http://physics.nist.gov/xaamdi, National Institute of Standards and Technology, 2004.

W. L. James, Y. Yen, and R. J. King, A microwave method for measuring moisture content, density, and grain angle of wood, 1985.

J. Johansson, O. Hagman, and A. Et-fjellner, Predicting moisture content and density distribution of Scots pine by microwave scanning of sawn timber, Journal of Wood Science, vol.49, issue.4, pp.312-316, 2003.
DOI : 10.1007/s10086-002-0493-7

P. Johns, M. Wismayer, and R. Et-leclair, The need for cross section data for medical xray scatter imaging. 5th Annual canadian light source users meeting, 2002.

R. Keller, Chapitre 1. La constitution du bois. Le bois matériau d'ingénierie, pp.14-52, 1994.

M. J. Key, Gas microestructure x-ray detectors and tomographic multiphase flow measurement, 1999.

J. Kirz, Scattering of X-rays from electrons and atoms. X-ray Data Booklet, 2001.

A. Kouchadé, Détermination en routine de la diffusivité massique dans le bois par la méthode inverse à partir de la mesure électrique en régime transitoire, Thèse ENGREF, 2004.

D. E. Kretschmann, H. A. Alden, and S. P. Verrill, Variations of microfibril angle in loblolly pine: comparison of iodine crystallization and x-ray diffraction techniques, pp.157-176, 1997.

M. A. Laskey and D. Phil, Dual-energy X-ray absorptiometry and body composition, Nutrition, vol.12, issue.1, pp.45-51, 1996.
DOI : 10.1016/0899-9007(95)00017-8

S. Leelavanichkul and A. Et-cherkaev, Why grain in tree's trunks spirals: mechanical perspective, International Journal of Structural Optimization, 2005.
DOI : 10.1007/s00158-003-0311-x

L. Leney, A technique for measuring fibril angle using polarized light, Wood and Fiber Science, vol.13, pp.13-16, 1981.

J. M. Létang, N. Freud, and G. Et-peix, Optimal calibration via virtual x-ray imaging for dual-energy techniques: application to glass wool, Sixth International Conference on Quality Control by Artificial Vision, 2003.
DOI : 10.1117/12.515145

H. Lichtenegger, M. Muller, O. Paris, and P. Fratzl, Imaging of the helical arrangement of cellulose fibrils in wood by synchrotron X-ray microdiffraction, Journal of Applied Crystallography, vol.32, issue.6, pp.1127-1133, 1999.
DOI : 10.1107/S0021889899010961

H. C. Lichtenegger, Variation of Cellulose Microfibril Angles in Softwoods and Hardwoods???A Possible Strategy of Mechanical Optimization, Journal of Structural Biology, vol.128, issue.3, pp.257-269, 1999.
DOI : 10.1006/jsbi.1999.4194

H. C. Lichtenegger, M. Müller, R. Wimmer, and P. Et-fratzl, Microfibril Angles Inside and Outside Crossfields of Norway Spruce Tracheids, Holzforschung, vol.57, issue.1, pp.13-20, 2003.
DOI : 10.1515/HF.2003.003

R. Liftig, Shop-built moisture meter. Fine Woodworking, pp.49-51, 1985.

J. Lindeberg, X-ray based tree ring analyses, p.25, 2004.

L. O. Lindgren, Medical CAT-scanning: X-ray absorption coefficients, CT-numbers and their relation to wood density, Wood Science and Technology, vol.25, issue.5, pp.341-349, 1991.
DOI : 10.1007/BF00226173

O. Lindgren, Zerst??rungsfreie Messung der Dichteverteilung in Holz mittels Computer-Tomographie, Holz als Roh- und Werkstoff, vol.68, issue.3, pp.295-299, 1992.
DOI : 10.1007/BF02615356

P. F. Lister, Application of X-ray computed tomography in the wood products industry, 2004.

C. J. Liu, J. R. Olson, Y. Tian, and Q. Et-shen, Theoretical wood densitometry: I. Mass attenuation equations and wood density models, Wood and Fiber Science, vol.20, issue.1, pp.22-34, 1988.

F. Longuetaud, Analyse non-destructive de caractéristiques internes de billons d'épicéa commun (Picea abies) par imagerie 3D à rayons X, 2004.

A. Macedo, C. M. Vaz, J. C. Pereira, J. M. Naime, P. E. Cruvinel et al., Wood Density Determination by X- and Gamma-Ray Tomography, Holzforschung, vol.56, issue.5, pp.535-540, 2002.
DOI : 10.1515/HF.2002.082

S. D. Magalhaes, J. Eichler, and O. Et-gonçalves, Calculation on x-ray scattering of 17, 1995.

J. F. Mcbride and C. T. Et-miller, Nondestructive measurements of phase fractions in multiphse porous-media experiments by using x-ray attenuation, pp.1-5, 1994.

S. Miyajima and K. Et-imagawa, CdZnTe detector in mammographic x-ray spectroscopy, Physics in Medicine and Biology, vol.47, issue.22, 2002.
DOI : 10.1088/0031-9155/47/22/304

S. Miyajima, H. Sakuragi, and M. Et-matsumoto, Extraction of mean free path of charge carriers in CdZnTe crystals from measured full-energy peaks. Nuclear Instruments and Methods in, Physics Research A, issue.485, pp.533-538, 2002.

S. Morales, A. Guesalaga, P. Fernandez, M. Guarini, and P. Et-irarrazaval, Computer reconstruction of pine growth rings using MRI, Magnetic Resonance Imaging, vol.22, issue.3, pp.403-412, 2004.
DOI : 10.1016/j.mri.2004.01.015

W. W. Moschler and E. F. Et-dougal, Calibration procedure for direct scanning densitometer using gamma radiation, Wood and Fiber Science, vol.3, issue.20, pp.297-303, 1988.

R. Newman, How stiff is an individual cellulose microfibril? Microfibril angle in wood, pp.81-93, 1997.

A. Niemelä, Low-noise electronics for high-resolution CdZnTe and CdTe X-ray detection systems. Rayons X et matière. 100 ans déjà, Journal de Physique IV, 1995.

P. Niemz, L. J. Kucera, H. W. Ridder, A. Habermehl, and A. Et-flisch, Durschblick mit Computertomographie, pp.7-10, 1998.

G. Norel, Etude des milieux poreux par absorption d'un rayonnement X ou gamma émis par une source radioactive, p.116, 1965.

J. Oja, S. Grundberg, J. Fredriksson, and P. Et-berg, Automatic grading of sawlogs: A comparison between X-ray scanning, optical three-dimensional scanning and combinations of both methods, Scandinavian Journal of Forest Research, vol.34, issue.1, pp.89-95, 2004.
DOI : 10.1080/02827580050160574

J. R. Olson, D. G. Arganbright, and S. G. Et-prussin, Use of an error analysis for evaluation of a dual-energy gamma radiation method for wood moisture content, Wood Science, vol.15, issue.1, pp.1-13, 1982.

M. Oostrom and J. H. Et-dave, Calibration and automation of a dual-energy gamma system for applications in soil science Agronomy and soils departamental series report N- 145, 1990.

S. Pang and P. Et-wiberg, Feuchteverteiiung in einem Kiefernbrett w??herend des Trocknens, gesch??tzt nach einem Modell und gemessen mittels Computertomographie (CT), Holz als Roh- und Werkstoff, vol.32, issue.8, pp.9-14, 1998.
DOI : 10.1007/s001070050256

T. Papp and J. L. Et-campbell, Size and origin of the escape peak in various Si(Li) detectors. x-ray spectrometry, pp.77-82, 2001.

P. Perré and I. Et-turner, Using a set of macroscopic equations to simulate heat and mass tranfer in porous media: some possibilities illustrated by a wide range of configurationss that emphasize the role of internal pressure. Numerical methods and mathematical modelling of the dryinf process, 1996.

P. Perré and F. Et-thiercelin, Determination de profils d'humidite dans le bois par détection directe de rayons-X: validation de la méthode, 1997.

P. Perré, Meshpore: A Software Able to Apply Image-Based Meshing Techniques to Anisotropic and Heterogeneous Porous Media, Proceeding of the 14th International Drying Symposium, 2004.
DOI : 10.1081/DRT-120004013

P. Perré and F. Et-thiercelin, Evidence of dual scale porous mechanism during fluid migration in hardwood species. (I) Using the attenuation of a polychromatic X-ray beam to determine the evolution of moisture content during imbibition of beech, Chinese Journal of Chemical Engineering, vol.12, issue.6, pp.773-782, 2004.

O. Peyret, C. Mestais, and L. Et-verger, Vers les gamma-caméras à semi-conducteurs, 1999.

M. E. Poletti, O. D. Gonçalves, and I. Et-mazzaro, X-ray scattering from human breast tissues and breast-equivalent materials, Physics in Medicine and Biology, vol.47, issue.1, pp.47-63, 2002.
DOI : 10.1088/0031-9155/47/1/304

M. E. Poletti, O. D. Gonçalves, and I. Et-mazzaro, Measurements of X-ray scatter signatures for some tissue-equivalent materials, Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, vol.213, pp.595-598, 2004.
DOI : 10.1016/S0168-583X(03)01676-8

H. Polge, Etablissement des courbes de variation de la densité du bois par exploration densitométrique des radiographies d'échantillons prélevés à la tarière sur des arbres vivants, 1966.

J. Ponpon and P. Et-siffert, Détecteurs de rayons X à semi-conducterurs. Evolutions récentes. Rayons X et matière. 100 ans déjà, Journal of Physique IV, 1995.
DOI : 10.1051/jp4:1996468

URL : https://hal.archives-ouvertes.fr/jpa-00254351/document

W. Press, S. Teukolsky, W. Vetterling, and B. Et-flannery, Numerical recipes in FORTRAN. The art of the scientific computing, 1992.

R. E. Prud-'homme and J. Et-noah, Determination of fibril angle distribution in wood fiber: a comparison between the X-ray diffraction and the polarized microscope methods, Wood and Fiber Science, vol.6, pp.282-289, 1975.

B. Redus, Charge trapping in XR-100T-CdTe and -CZT detectors. Application Note ANCZT-2 Rev. 2. [Online] Available, 2003.

A. Reiterer, H. C. Lichtenegger, S. E. Stanzl-tschegg, and P. Et-fratzl, Experimental evidence for a mechanical function of the cellulose microfibril angle in wood cell walls, Philosophical Magazine A, vol.4, issue.9, pp.2173-2184, 1999.
DOI : 10.1007/BF00702790

R. Rémond, Approche déterministe du séchage des avivés de résineux des fortes épaisseurs pour proposer des conduites industrielles adaptées. ENGREF, p.219, 2004.

R. Rémond, E. Mougel, and P. Et-perré, Using the Concept of Thin Dry Layer to Explain the Evolution of Thickness, Temperature, and Moisture Content during Convective Drying of Norway Spruce Boards, Drying Technology, vol.4, issue.1-2, pp.249-271, 2005.
DOI : 10.1081/DRT-120028202

A. Rinnhofer, A. Petutschnigg, and J. Et-andreu, Internal log scanning for optimizing breakdown, Computers and Electronics in Agriculture, vol.41, issue.1-3, pp.7-21, 2003.
DOI : 10.1016/S0168-1699(03)00039-5

M. Risinger, Neutron moisture meters, 2004.

E. Rosenberg, J. Schatvet, and K. Et-hoydal, In-kiln measurements of moisture content in timber at Moelven Valer AS, 2001.

A. Rosenkilde and P. Et-glover, High Resolution Measurement of the Surface Layer Moisture Content during Drying of Wood Using a Novel Magnetic Resonance Imaging Technique, Holzforschung, vol.56, issue.3, pp.312-317, 2002.
DOI : 10.1515/HF.2002.050

H. Sahin and N. Et-ay, Dielectric properties of hardwood species at microwave frequencies, Journal of Wood Science, vol.50, issue.4, pp.375-380, 2004.
DOI : 10.1007/s10086-003-0575-1

U. Sahlberg, L. Salmén, and A. Et-oscarsson, The fibrillar orientation in the S2-layer of wood fibres as determined by X-ray diffraction analysis, Wood Science and Technology, vol.4, issue.3, pp.77-86, 1997.
DOI : 10.1007/BF00705923

K. C. Schad, D. Schmoldt, and R. J. Et-ross, Nondestructive methods for detecting defects in softwood logs, 1996.

G. Schena, C. Chiaruttini, D. Dreossi, A. Olivo, and S. Et-pani, Grade of fine composite mineral particles by dual-energy X-ray radiography, International Journal of Mineral Processing, vol.67, issue.1-4, pp.101-122, 2002.
DOI : 10.1016/S0301-7516(02)00037-6

D. Schmoldt, J. He, and A. L. Abbott, <title>Comparison of several artificial neural network classifiers for CT images of hardwood logs</title>, Machine Vision Applications in Industrial Inspection VI, 1998.
DOI : 10.1117/12.301243

D. L. Schmoldt, CT imaging, data reduction, and visualization of hardwood logs, Hardwood Symposium, 1996.

P. Sepúlveda, Measurement of spiral grain with computed tomography, Journal of Wood Science, vol.15, issue.2, pp.289-293, 2001.
DOI : 10.1007/BF00766715

P. Sepúlveda, D. E. Kline, and J. Et-oja, Prediction of fiber orientation in Norway spruce logs using an X-ray logs scanner: a preliminary study, Wood and Fiber Science, vol.35, issue.3, pp.421-428, 2003.

X. Shi, Improving object classification in X-ray luggage inspection, p.212, 2000.

J. Siau, Transport process in wood, 1984.

P. R. Steiner, L. A. Jozsa, M. L. Parker, and S. Et-chow, Application of x-ray densitometry to determine density profile in waferboard: relationship of density to thickness expansion and internal bond strength under various cycles, Wood Science, vol.11, issue.1, pp.48-55, 1978.

A. Tartari, A. Taibi, C. Bonifazzi, and C. Et-baraldi, Updating of form factor tabulations for coherent scattering of photons in tissues, Physics in Medicine and Biology, vol.47, issue.1, pp.163-175, 2002.
DOI : 10.1088/0031-9155/47/1/312

S. P. Verrill, D. E. Kretschmann, and V. L. Et-herian, JMFA -A graphically interactive java program that fits microfibril angle x-ray diffraction data, 2001.

J. Vion-dury, Cours de résonance magnétique: spectrométrie et imagerie, 2002.

N. Walker and R. Et-dodd, Calculation of wood density variation from x-ray densitometer data, Wood and Fiber Science, vol.1, issue.20, pp.35-43, 1988.

P. Wiberg and T. J. Et-morén, Moisture flux determination in wood during drying above fibre saturation point using CT-scanning and digital image processing, Holz als Roh- und Werkstoff, vol.57, issue.2, pp.137-144, 1999.
DOI : 10.1007/s001070050029