R. Globaux, D. Vue-anterieure-;-b, P. Vue, A. Tendu, A. De-5 et al., 30 FIGURE 14 : 31 FIGURE 15, CONTOURS SELECTIONNES IN VITRO (A) ET IN VIVO (B), pp.71-112, 1941.

R. Bleu, M. Actuelle, . En, M. Violet, S. Bassin et al., 93 FIGURE 53 : DISTANCESETAPE 1.2) 103 FIGURE 60 : EVALUATION 103 FIGURE 61 103 FIGURE 63, 103 FIGURE 88 : OUTILS DE COMPARAISON ENTRE DE OBJETS. COMPARAISON QUALITATIVE PAR SUPERPOSITION DES DEUX OBJETS (MAUVE : REFERENCE, JAUNE : RECONSTRUCTION), B) CARTOGRAPHIE DES ERREURS DE RECONSTRUCTION SUR L'OBJET RECONSTRUIT (DU BLEU AU ROUGE : 0 MM A ERREUR MAXIMALE), C) VISUALISATION DES DISTANCES POINT/SURFACE (BLEU : ERREUR < 1 MM, VERT : ERREUR < 3 MM), D) GRAPHE, pp.103-149, 2002.

Y. Bibliographieabdel-aziz and H. Karara, Direct linear transformation from comparator coordinates into object space coordinates in close-range photogrammetry, 1971.

F. Baylac, Contribution à la semi-automatisation de la reconstruction tridimensionnelle du bassin par stéréoradiographie, LBM. Paris, ENSAM. PFE, 2003.

C. Boulay, Morphométrie comparative anatomo-radiologique du bassin humain. LBM, 1997.

C. Boulay, Validit?? anatomique de deux param??tres pelviens radiologiques et cliniques: l???incidence et l?????paisseur, European Journal of Orthopaedic Surgery & Traumatology, vol.11, issue.3, p.197, 2005.
DOI : 10.1007/s00590-005-0239-5

N. S. Broughton, Reliability of radiological measurements in the assessment of the child's hip, J Bone Joint Surg Br, vol.71, issue.1, pp.6-8, 1989.

R. H. Brown, Spinal analysis using a three-dimensional radiographic technique, Journal of Biomechanics, vol.9, issue.6, pp.355-65, 1976.
DOI : 10.1016/0021-9290(76)90113-5

C. Cabrol, Anatomie de l'appareil locomoteur, 1990.

J. L. Cartier, La cupule à double mobilité: Principes defonctionnement. Spécificités opératoires, Maîtrise Orthopédique, vol.121, 2003.

S. Champain, Validation of new clinical quantitative analysis software applicable in spine orthopaedic studies, European Spine Journal, vol.210, issue.1, pp.982-91, 2006.
DOI : 10.1007/s00586-005-0927-1

E. Y. Chao and K. Rim, Application of optimization principles in determining the applied moments in human leg joints during gait, Journal of Biomechanics, vol.6, issue.5, pp.497-510, 1973.
DOI : 10.1016/0021-9290(73)90008-0

J. M. Chevalier, Anatomie de l'appareil locomoteur, 2000.

J. Dansereau and I. A. Stokes, Measurements of the three-dimensional shape of the rib cage, Journal of Biomechanics, vol.21, issue.11, pp.893-901, 1988.
DOI : 10.1016/0021-9290(88)90127-3

E. De-momi, Year] 3D shape iterative reconstruction method based on statistical models, 6th Annual Meeting of CAOS-International Proceedings

C. Delaunay, Prothèse totale de Charnley: où en est aujourd'hui le "gold standart" de l'arthroplastie primaire de hanche, Maîtrise Orthopédique, 1999.

C. Delaunay, Les luxations precoces de prothèses totales de hanche. Quoi de neuf depuis dix ans, Maîtrise Orthopédique, 2001.

S. Delaunay, Radiographic measurements of dysplastic adult hips, Skeletal Radiology, vol.26, issue.2, pp.75-81, 1997.
DOI : 10.1007/s002560050197

D. A. Dennis, Dealing with dislocation, 13th Annual Current Concepts in joint replacement proceedings, 1997.

X. Dong, Fully automatic estimation of geometrical parameters of proximal femur from calibrated X-ray images through particle filtering, Proceedings of the 6th annaul meeting of CAOS-International, 2006.

J. Dubousset, The Pediatric Spine: principles and practice, 1994.

J. Dubousset, The Textbook of Spinal Surgery: Cotrel-Dubousset instrumentation for paralytic neuromuscular deformities with emphasis on pelvic obliquity, 1991.

J. Dubousset, [A new 2D and 3D imaging approach to musculoskeletal physiology and pathology with low-dose radiation and the standing position: the EOS system], Bull Acad Natl Med, vol.189, issue.2, pp.287-97, 2005.

R. Dumas, Explicit calibration method and specific device designed for stereoradiography, Journal of Biomechanics, vol.36, issue.6, pp.827-861, 2003.
DOI : 10.1016/S0021-9290(03)00016-2

M. Fleute, Incorporating a statistically based shape model into a system for computer-assisted anterior cruciate ligament surgery, Medical Image Analysis, vol.3, issue.3, pp.209-231, 1999.
DOI : 10.1016/S1361-8415(99)80020-6

R. G. Haaker, Comparison of Conventional Versus Computer-Navigated Acetabular Component Insertion, The Journal of Arthroplasty, vol.22, issue.2, pp.151-160, 2007.
DOI : 10.1016/j.arth.2005.10.018

L. Humbert, 3D Evaluation of the acetabular coverage assessed by biplanar X-rays or single anteroposterior X-ray compared with CT-scan, Computer Methods in Biomechanics and Biomedical Engineering, vol.26, issue.3, 2007.
DOI : 10.1007/s00256-005-0050-8

L. Humbert, 3D RECONSTRUCTION OF THE SPINE FROM BIPLANAR X-RAYS USING LONGITUDINAL AND TRANSVERSAL INFERENCES, Journal of Biomechanics, vol.40, issue.1, 2007.
DOI : 10.1016/S0021-9290(07)70156-2

S. Jacobsen, Degeneration in dysplastic hips, Skeletal Radiology, vol.36, issue.Suppl 1, pp.778-84, 2005.
DOI : 10.1007/s00256-005-0019-7

S. Jacobsen, Pelvic orientation and assessment of hip dysplasia in adults, Acta Orthopaedica Scandinavica, vol.37, issue.6, pp.721-730, 2004.
DOI : 10.1080/00016470410004094

G. Kalifa, Evaluation of a new low-dose digital X-ray device: first dosimetric and clinical results in children, Pediatric Radiology, vol.28, issue.7, pp.557-61, 1998.
DOI : 10.1007/s002470050413

M. Kitajima, A simple method to determine the pelvic inclination angle based on anteroposterior radiographs, Journal of Orthopaedic Science, vol.11, issue.4, pp.342-348, 2006.
DOI : 10.1007/s00776-006-1020-2

S. Laporte, Reconstruction 3D du squelette humain pour la biomécanique par radiographie biplane à dose minimale d'irradiation. LBM, 2002.

S. Laporte, A Biplanar Reconstruction Method Based on 2D and 3D Contours: Application to the Distal Femur, Computer Methods in Biomechanics and Biomedical Engineering, vol.17, issue.1, pp.1-6, 2003.
DOI : 10.1016/S0169-2607(98)00107-2

F. Lavaste, Three-dimensional geometrical and mechanical modelling of the lumbar spine, Journal of Biomechanics, vol.25, issue.10, pp.1153-64, 1992.
DOI : 10.1016/0021-9290(92)90071-8

J. Y. Lazennec, Hip-spine relationship: a radio-anatomical study for optimization in acetabular cup positioning, Surg Radiol Anat, vol.26, issue.2, pp.136-180, 2004.

J. Y. Lazennec, Hip spine relationships: application to total hip arthroplasty, Hip International, vol.17, issue.Suppl. 5, 2007.
DOI : 10.5301/HIP.2008.1228

A. Le-bras, 3D reconstruction of the proximal femur with low-dose digital stereoradiography, Computer Aided Surgery, vol.57, issue.11, pp.51-58, 2004.
DOI : 10.1359/jbmr.1999.14.10.1714

J. Legaye, Pelvic incidence: a fundamental pelvic parameter for three-dimensional regulation of spinal sagittal curves, European Spine Journal, vol.7, issue.2, pp.99-103, 1998.
DOI : 10.1007/s005860050038

M. Lequesne and S. De-se, Le faux profil du bassin. Nouvelle incidence radiographique pour l'e?tude de la hanche. Son utilite? dans les dysplasies et les differentes coxopathies, Rev Rhum Mal Osteoartic, vol.28, p.643, 1961.

M. Lequesne, The normal hip joint space: variations in width, shape, and architecture on 223 pelvic radiographs, Annals of the Rheumatic Diseases, vol.63, issue.9, pp.1145-51, 2004.
DOI : 10.1136/ard.2003.018424

G. E. Lewinnek, Dislocations after total hip-replacement arthroplasties., The Journal of Bone & Joint Surgery, vol.60, issue.2, pp.217-237, 1978.
DOI : 10.2106/00004623-197860020-00014

M. Maruyama, The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning, Clin Orthop Relat Res, issue.393, pp.52-65, 2001.

T. Masaoka, Study of hip joint dislocation after total hip arthroplasty, International Orthopaedics, vol.119, issue.6, pp.26-30, 2006.
DOI : 10.1007/s00264-005-0032-4

E. Mayr, The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: Spatial orientation of the pelvis in different positions, Acta Orthopaedica, vol.52, issue.411, pp.848-53, 2005.
DOI : 10.1080/17453670510045471

P. Messmer, Volumetric Model Determination of the Tibia Based on 2D Radiographs Using a 2D/3D Database, Computer Aided Surgery, vol.11, issue.4, pp.183-94, 2001.
DOI : 10.1016/S1361-8415(99)80020-6

A. Milcan, The anterior center edge angle: a study of 102??volunteers, Joint Bone Spine, vol.71, issue.3, pp.221-224, 2004.
DOI : 10.1016/S1297-319X(03)00121-0

D. Mitton, 3D reconstruction of the pelvis from bi-planar radiography, Computer Methods in Biomechanics and Biomedical Engineering, vol.212, issue.1, pp.1-5, 2006.
DOI : 10.1007/BF01206346

D. Mitton, Head to feet 3D reconstruction from biplanar X-rays in standing position. Bioengineering modelling and computer simulation, pp.57-71, 2007.

D. Mitton, 3D reconstruction method from biplanar radiography using non-stereocorresponding points and elastic deformable meshes, Medical and Biological Engineering and Computing, vol.9, issue.2, pp.133-142, 2000.
DOI : 10.1007/BF02344767

A. Mitulescu, Contribution à la reconstruction tridimensionnelle du rachis et du bassin à partir de la stéréoradiographie conventionnelle et basse dose (CHARPAK). LBM, 2001.

A. Mitulescu, 3D reconstruction of the pelvis using the NSCP technique, Stud Health Technol Inform, vol.88, pp.177-81, 2002.

B. F. Morrey, Difficult complications after hip joint replacement. Dislocation, Clin Orthop Relat Res, issue.344, pp.179-87, 1997.
DOI : 10.1097/00003086-199711000-00019

S. Nakamura, Evaluation of acetabular dysplasia using a top view of the hip on three-dimensional CT, Journal of Orthopaedic Science, vol.5, issue.6, pp.533-542, 2000.
DOI : 10.1007/s007760070001

M. Nelitz, Reliability of radiological measurements in the assessment of hip dysplasia in adults., The British Journal of Radiology, vol.72, issue.856, pp.331-335, 1999.
DOI : 10.1259/bjr.72.856.10474491

S. Ogata, Acetabular cover in congenital dislocation of the hip, J Bone Joint Surg Br, vol.72, issue.2, pp.190-196, 1990.

H. Omeroglu, Measurement of center-edge angle in developmental dysplasia of the hip: a comparison of two methods in patients under 20??years of age, Skeletal Radiology, vol.31, issue.1, pp.25-34, 2002.
DOI : 10.1007/s002560100402

M. J. Pearcy, Stereo radiography of lumbar spine motion, Acta Orthopaedica Scandinavica, vol.23, issue.sup212, pp.1-45, 1985.
DOI : 10.1097/00007632-198107000-00010

F. Pierchon, Causes of dislocation of total hip arthroplasty. CT study of component alignment, J Bone Joint Surg Br, vol.76, issue.1, pp.45-53, 1994.

V. Pomero, Fast accurate stereoradiographic 3D-reconstruction of the spine using a combined geometric and statistic model, Clinical Biomechanics, vol.19, issue.3, pp.240-247, 2004.
DOI : 10.1016/j.clinbiomech.2003.11.014

V. Pomero and W. Skalli, Radiographic imaging method for three-dimensional reconstruction, device and computer software for carrying out said method, 2004.

P. Pouletaut, Automated analysis of MR image of hip: geometrical evaluation of the Legg???Calv?????Perthes disease, Medical Engineering & Physics, vol.27, issue.5, pp.415-439, 2005.
DOI : 10.1016/j.medengphy.2004.10.003

T. Sato, Three-dimensional lower extremity alignment assessment system, The Journal of Arthroplasty, vol.19, issue.5, pp.620-628, 2004.
DOI : 10.1016/j.arth.2003.12.063

G. Saxler, The accuracy of free-hand cup positioning - a CT based measurement of cup placement in 105 total hip arthroplasties, International Orthopaedics, vol.28, issue.4, pp.198-201, 2004.
DOI : 10.1007/s00264-004-0542-5

G. Selvik, Roentgen stereophotogrammetry. A method for the study of the kinematics of the skeletal system, Acta Orthop Scand, vol.232, pp.1-51, 1989.

E. Severin, Contribution to the knowledge of congenital dislocation of the hip joint, Acta Chir Scand, vol.84, p.1, 1941.

W. Skalli, E. France, and . Cnrs, Stereoradiography device and method for the use thereof, 2003.

E. S. Stem, Computed tomography analysis of acetabular anteversion and abduction, Skeletal Radiology, vol.417, issue.6, pp.385-394, 2006.
DOI : 10.1007/s00256-006-0086-4

I. A. Stokes, Assessment of Patients With Low-Back Pain by Biplanar Radiographic Measurement of Intervertebral Motion, Spine, vol.6, issue.3, pp.233-273, 1981.
DOI : 10.1097/00007632-198105000-00005

C. H. Suh, The fundamentals of computer aided X-ray analysis of the spine, Journal of Biomechanics, vol.7, issue.2, pp.161-170, 1974.
DOI : 10.1016/0021-9290(74)90057-8

T. V. Swanson, Intérêt dans la PTH d'une voie d'abord postérieure unique et courte avec la tige sans ciment SL-Plus, Maîtrise Orthopédique 141, 2004.

K. Tallroth and J. Lepisto, Computed tomography measurement of acetabular dimensions: Normal values for correction of dysplasia, Acta Orthopaedica, vol.83, issue.363, pp.598-602, 2006.
DOI : 10.1007/978-3-642-71038-4

F. Trochu, A contouring program based on dual kriging interpolation, Engineering with Computers, vol.79, issue.2, pp.160-177, 1993.
DOI : 10.1007/BF01206346

S. Véron, Modélisation géométrique et mécanique tridimensionelle par éléments finis du rachis cervical supérieur. LBM, 1997.

G. Wiberg, Studies on dysplastic acetabula and congenital subluxation of the hip joint. With special reference to the complication of osteoarthritis 58): 1. Publications & communications Publications à revues internationales avec comité de lecture '3D Evaluation of the acetabular coverage assessed by biplanar X-rays or single anteroposterior X-ray compared with CT-scan, Acta Chir Scand, vol.83, 1939.

L. Humbert, H. Carlioz, A. Baudoin, W. Skalli, and D. , Mitton Accepté dans Computer Method in Biomechanics and Biomedical Engineering CMBBE Communications à congrès scientifiques internationaux avec comité de lecture et actes 'A new method for the evaluation of total hip arthroplasty based on bi-planar low dose X-rays

A. Baudoin, Y. Lazennec, . Catonne, . Gorin, D. Dubousset et al., The EOS 2D-3D X-ray scanner : a new technology to assess the tridimensional position of THA cups Paris(France) 'The EOS? low irradiation 2D-3D x-ray scanner -a new technology to assess the real tridimensionnal position of T.H.P. implants' JY Lazennec Catonne 15th Triennial congress of Asia Pacific Orthopaedic Association (APOA)Parametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: Application to the upper femoral extremityParametric subject-specific model for in vivo 3D reconstruction using bi-planar X-rays: Application to the upper femoral extremity' A. BaudoinAn accurate pelvis axis sytem using a low dose X-ray device, Skalli 20th annual congress of the International Society for Technology in Arthroplasty (ISTA) Catonne 20th annual congress of the International Society for Technology in Arthroplasty (ISTA) Mitton 21st congress of the International Society of Biomechanics (ISB) Skalli, D. Mitton 21st congress of Computer Assisted Radiology and Surgery (CARS) Baudoin, W. Skalli, D. Mitton 6th annual meeting of Computer Assisted Orthopaedic Surgery (CAOS), 2006.