B. Acar and G. Yi, Spatial, temporal and wavefront direction characteristics of 12-lead T-wave morphology, Medical & Biological Engineering & Computing, vol.74, issue.5, pp.574-84, 1999.
DOI : 10.1007/BF02513351

E. Aliot and R. Nitzsche, Arrhythmia detection by dual-chamber implantable cardioverter defibrillatorsA review of current algorithms, Europace, vol.6, issue.4, pp.273-86, 2004.
DOI : 10.1016/j.eupc.2004.02.005

D. Bansch and F. Steffgen, The 1+1 Trial: A Prospective Trial of a Dual- Versus a Single-Chamber Implantable Defibrillator in Patients With Slow Ventricular Tachycardias, Circulation, vol.110, issue.9, pp.1022-1031, 2004.
DOI : 10.1161/01.CIR.0000140259.16185.7D

G. Boriani and M. Biffi, Clinical Evaluation of Morphology Discrimination: An Algorithm for Rhythm Discrimination in Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.6, pp.994-1001, 2001.
DOI : 10.1046/j.1460-9592.2001.00994.x

G. Boriani and E. Occhetta, Contribution of morphology discrimination algorithm for improving rhythm discrimination in slow and fast ventricular tachycardia zones in dual-chamber implantable cardioverter-defibrillators, Europace, vol.10, issue.8, pp.918-943, 2008.
DOI : 10.1093/europace/eun146

G. Boriani and E. Occhetta, Combined Use of Morphology Discrimination, Sudden Onset, and Stability as Discriminating Algorithms in Single Chamber Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.25, issue.9, pp.1357-66, 2002.
DOI : 10.1046/j.1460-9592.2002.01357.x

P. Bouchet and R. Dubois, Spatial Projection of Tachycardia Electrograms for Morphology Discrimination in Implantable Cardioverter Defibrillators, IEEE Proc. Computers in Cardiology, vol.36, pp.9-12, 2009.

C. Butter and A. Auricchio, Clinical Evaluation of a Prototype Passive Fixation Dual Chamber Single Pass Lead For Dual Chamber ICD Systems, Pacing and Clinical Electrophysiology, vol.19, issue.1, 1999.
DOI : 10.1111/j.1540-8159.1999.tb00326.x

D. A. Chamberlain and D. J. Woollons, Synchronous AV pacing with a single pervenous electrode, Br Heart J, vol.35, issue.5, p.559, 1973.

S. Chen and S. A. Billings, Orthogonal least squares methods and their application to non-linear system identification, International Journal of Control, vol.10, issue.5, pp.1873-1896, 1989.
DOI : 10.2307/2284566

S. J. Compton and J. J. Merrill, Continuous Template Collection and Updating for Electrogram Morphology Discrimination in Implantable Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.3, pp.244-54, 2006.
DOI : 10.1046/j.1540-8167.2002.00432.x

R. Corbisiero and M. A. Lee, Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation, Europace, vol.8, issue.12, pp.1057-61, 2006.
DOI : 10.1093/europace/eul119

J. P. Daubert and W. Zareba, Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II, Journal of the American College of Cardiology, vol.51, issue.14, pp.1357-65, 2008.
DOI : 10.1016/j.jacc.2007.09.073

P. Diotallevi and P. A. Ravazzi, An Algorithm for Verifying Biventricular Capture Based on Evoked-Response Morphology, Pacing and Clinical Electrophysiology, vol.23, issue.s1, pp.15-23, 2005.
DOI : 10.1111/j.1540-8159.2005.00099.x

G. Dreyfus and J. Martinez, Apprentissage Statistique ? Réseaux de neurones, cartes topologiques, machines à vecteurs supports, 2008.

F. Extramiana and A. Haggui, T-Wave Morphology Parameters Based on Principal Component Analysis Reproducibility and Dependence on T???Offset Position, Annals of Noninvasive Electrocardiology, vol.23, issue.4, pp.354-63, 2007.
DOI : 10.1111/j.1365-2796.2005.01587.x

M. R. Gold and W. Hsu, A New Defibrillator Discrimination Algorithm Utilizing Electrogram Morphology Analysis, Pacing and Clinical Electrophysiology, vol.14, issue.1, pp.179-82, 1999.
DOI : 10.1016/S0002-9149(97)00633-4

M. R. Gold and S. R. Shorofsky, Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation, Journal of Cardiovascular Electrophysiology, vol.13, issue.11, pp.1092-1099, 2002.
DOI : 10.1046/j.1540-8167.2002.01092.x

R. Gradaus and B. D. Gonska, European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead, Pacing and Clinical Electrophysiology, vol.25, issue.7, pp.1079-86, 2002.
DOI : 10.1046/j.1460-9592.2002.01079.x

A. Hyvärinen and J. Karhunen, Independent Component Analysis, 2002.

I. T. Jolliffe, Principal Component Analysis, Second Edition, 2002.

G. J. Klein and J. M. Gillberg, Improving SVT Discrimination in Single-Chamber ICDs: A New Electrogram Morphology-Based Algorithm, Journal of Cardiovascular Electrophysiology, vol.103, issue.12, 2006.
DOI : 10.1111/j.1540-8159.2000.tb00919.x

C. Linde and I. Kruse, Acute and long? term experience with a new single lead for VDD pacing, Eur J Cardiac Pacing Electrophysiol, vol.4, pp.274-82, 1992.

E. Longo and V. Catrini, Experience and Implantation Techniques with a New Single-Pass Lead VDD Pacing System, Pacing and Clinical Electrophysiology, vol.9, issue.7, pp.927-963, 1990.
DOI : 10.1111/j.1540-8159.1990.tb02130.x

L. Luthje and D. Vollmann, Electrogram Configuration and Detection of Supraventricular Tachycardias by a Morphology Discrimination Algorithm in Single Chamber ICDs, Pacing and Clinical Electrophysiology, vol.23, issue.6, pp.555-60, 2005.
DOI : 10.1016/S0002-9149(96)00501-2

P. Milpied and R. Dubois, Morphological Stability of Bipolar and Unipolar Endocardial Electrograms, IEEE Proc. Computers in Cardiology, vol.37, pp.733-736, 2010.

B. Naegeli and S. Osswald, VDD(R) Pacing: Short- and Long-Term Stability of Atrial Sensing with a Single Lead System, Pacing and Clinical Electrophysiology, vol.116, issue.4, pp.455-64, 1996.
DOI : 10.1111/j.1540-8159.1996.tb06516.x

B. Naegeli and E. Straumann, Dual Chamber Pacing with a Single-Lead DDD Pacing System, Pacing and Clinical Electrophysiology, vol.19, issue.7, pp.1013-1022, 1999.
DOI : 10.1111/j.1540-8159.1999.tb00565.x

M. Niehaus and M. De-sousa, Chronic Experiences with a Single Lead Dual Chamber Implantable Cardioverter Defibrillator System, Pacing and Clinical Electrophysiology, vol.21, issue.10, p.1937, 2003.
DOI : 10.1046/j.1460-9592.2001.00183.x

E. Occhetta and M. Bortnik, Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias, Europace, vol.8, issue.10, pp.863-872, 2006.
DOI : 10.1093/europace/eul093

URL : http://europace.oxfordjournals.org/cgi/content/short/8/10/863

J. J. Rieta and F. Castells, Atrial Activity Extraction for Atrial Fibrillation Analysis Using Blind Source Separation, IEEE Transactions on Biomedical Engineering, vol.51, issue.7, pp.1176-1186, 2004.
DOI : 10.1109/TBME.2004.827272

O. H. Schmitt and E. Simonson, SYMPOSIUM ON ELECTROCARDIOGRAPHY AND VECTORCARDIOGRAPHY, A.M.A. Archives of Internal Medicine, vol.96, issue.5, pp.574-90, 1955.
DOI : 10.1001/archinte.1955.00250160016002

A. Schuchert and M. Niehaus, Feasibility of atrial sensing via a free?floating single? pass defibrillation lead for dual?chamber defibrillators, Journal of Interventional Cardiac Electrophysiology, vol.8, issue.3, pp.209-223, 2003.
DOI : 10.1023/A:1023921322671

B. Schulte and J. Sperzel, Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials, Journal of Interventional Cardiac Electrophysiology, vol.5, issue.4, pp.487-93, 2001.
DOI : 10.1023/A:1013214516002

M. Stone, Cross?Validatory Choice and Assessment of Statistical Predictions, Journal of the Royal Statistical Society. Series B (Methodological), vol.36, issue.2, pp.111-147, 1974.

H. Stoppiglia and G. Dreyfus, Ranking a random feature for variable and feature selection, JMLR.org, vol.3, pp.1399-1414, 2003.

M. Stridh and L. Sornmo, Spatiotemporal QRST cancellation techniques for analysis of atrial fibrillation, IEEE Transactions on Biomedical Engineering, vol.48, issue.1, pp.105-111, 2001.
DOI : 10.1109/10.900266

C. D. Swerdlow and M. L. Brown, Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet-Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms, Journal of Cardiovascular Electrophysiology, vol.13, issue.5, pp.432-473, 2002.
DOI : 10.1046/j.1540-8167.2002.00432.x

D. A. Theuns and M. Rivero?ayerza, Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates, Europace, vol.10, issue.9, pp.1060-1066, 2008.
DOI : 10.1093/europace/eun194

D. A. Theuns and M. Rivero?ayerza, Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators, Heart Rhythm, vol.3, issue.11, pp.1332-1340, 2006.
DOI : 10.1016/j.hrthm.2006.06.034

D. Urbani and P. Roussel?ragot, The selection of neural models of nonlinear dynamical systems by statistical tests, Proceedings of IEEE Workshop on Neural Networks for Signal Processing, 1994.
DOI : 10.1109/NNSP.1994.366044

V. Vapnik, The Nature of Statistical Learning Theory, 1995.

P. Varriale and A. G. Pilla, Single-Lead VDD Pacing System, Pacing and Clinical Electrophysiology, vol.11, issue.4, pp.757-66, 1990.
DOI : 10.1016/0002-9149(87)91179-9

F. N. Wilson and F. D. Johnston, The vectorcardiogram, American Heart Journal, vol.16, issue.1, pp.14-28, 1938.
DOI : 10.1016/S0002-8703(38)90899-3

T. Wolber and C. Binggeli, Wavelet-Based Tachycardia Discrimination in ICDs: Impact of Posture and Electrogram Configuration, Pacing and Clinical Electrophysiology, vol.6, issue.1, pp.1255-60, 2006.
DOI : 10.1111/j.1540-8159.2005.50011.x

X. H. Zhou and N. A. Obuchowski, Statistical Methods in Diagnostic Medicine, 2002.

P. Milpied, R. Dubois, P. Roussel, C. Henry, G. Dreyfus et al., Arrhythmia Discrimination in Implantable Cardioverter Defibrillators using Support Vector Machines applied to a new Representation of Electrograms Stability of bipolar and unipolar endocardial electrograms Arrhythmia classification using spatial projection of tachycardia electrograms, Compte­rendus de conférences Atrial activity extraction in single?chamber implantable defibrillators, pp.733-736, 2010.

D. Herpin, P. Bouchet, R. Dubois, C. Henry, P. Roussel et al., Spatial projection of tachycardia electrograms for morphology discrimination in implantable cardioverter defibrillators Dispositif médical actif comprenant des moyens de détection et de filtrage d'artéfacts par analyse du vectogramme cardiaque, Europace IEEE Proc. Computers in Cardiology, vol.12, issue.36, 2009.

J. P. Daubert, W. Zareba, D. S. Cannom, S. Mcnitt, S. Z. Rosero et al., Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II, Journal of the American College of Cardiology, vol.51, issue.14, pp.1357-65, 2008.
DOI : 10.1016/j.jacc.2007.09.073

C. D. Swerdlow, M. L. Brown, K. Lurie, J. Zhang, N. M. Wood et al., Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet-Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms, Journal of Cardiovascular Electrophysiology, vol.13, issue.5, pp.432-473, 2002.
DOI : 10.1046/j.1540-8167.2002.00432.x

M. R. Gold, S. R. Shorofsky, J. A. Thompson, J. Kim, M. Schwartz et al., Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation, Journal of Cardiovascular Electrophysiology, vol.13, issue.11, pp.1092-1099, 2002.
DOI : 10.1046/j.1540-8167.2002.01092.x

G. Boriani, M. Biffi, L. Frabetti, J. J. Lattuca, and A. Branzi, Clinical Evaluation of Morphology Discrimination: An Algorithm for Rhythm Discrimination in Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.6, pp.994-1001, 2001.
DOI : 10.1046/j.1460-9592.2001.00994.x

. Branzi, Combined use of morphology discrimination, sudden onset, and stability as discriminating algorithms in single chamber cardioverter defibrillators, Pacing Clin Electrophysiol, vol.25, pp.1357-66, 2002.

L. Luthje, D. Vollmann, M. Rosenfeld, and C. Unterberg-buchwald, Electrogram Configuration and Detection of Supraventricular Tachycardias by a Morphology Discrimination Algorithm in Single Chamber ICDs, Pacing and Clinical Electrophysiology, vol.23, issue.6, pp.555-60, 2005.
DOI : 10.1016/S0002-9149(96)00501-2

T. Wolber, C. Binggeli, J. Holzmeister, C. Brunckhorst, U. Strobel et al., Wavelet-Based Tachycardia Discrimination in ICDs: Impact of Posture and Electrogram Configuration, Pacing and Clinical Electrophysiology, vol.6, issue.1, pp.1255-60, 2006.
DOI : 10.1111/j.1540-8159.2005.50011.x

M. Kotas, Projective Filtering of Time-Aligned ECG Beats, IEEE Transactions on Biomedical Engineering, vol.51, issue.7, pp.1129-1168, 2004.
DOI : 10.1109/TBME.2004.826592

P. Bouchet, R. Dubois, C. Henry, P. Roussel, and G. Dreyfus, Spatial Projection of Tachycardia Electrograms for Morphology Discrimination in Implantable Cardioverter Defibrillators, IEEE Proc. Computers in Cardiology, vol.36, pp.9-12, 2009.

D. A. Theuns, M. Rivero-ayerza, D. M. Goedhart, R. Van-der-perk, and L. J. Jordaens, Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators, Heart Rhythm, vol.3, issue.11, pp.1332-1340, 2006.
DOI : 10.1016/j.hrthm.2006.06.034

V. Vapnik, The Nature of Statistical Learning Theory, 1995.

M. Stone, Cross-validatory choice and assessment of statistical predictions, J Roy Statist Soc Ser B, vol.36, pp.111-147, 1974.

X. H. Zhou, N. A. Obuchowski, and D. K. Mcclish, Statistical methods in diagnostic medicine, 2002.

S. J. Compton, J. J. Merrill, P. Dorian, J. Cao, D. Zhou et al., Continuous Template Collection and Updating for Electrogram Morphology Discrimination in Implantable Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.3, pp.244-54, 2006.
DOI : 10.1046/j.1540-8167.2002.00432.x

D. A. Theuns, M. Rivero-ayerza, D. M. Goedhart, M. Miltenburg, L. J. Jordaens et al., Morphology discrimination in implantable cardioverterdefibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates Stability of bipolar and unipolar endocardial electrograms Inappropriate Implantable Cardioverter Defibrillator Shocks in MADIT II, IEEE Proc. Computing in Cardiology, pp.1060-1066, 2008.

C. Swerdlow, M. Brown, K. Lurie, J. Zhang, N. Wood et al., Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet-Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms, Journal of Cardiovascular Electrophysiology, vol.13, issue.5, pp.432-441, 2002.
DOI : 10.1046/j.1540-8167.2002.00432.x

M. Gold, S. Shorofsky, J. Thompson, J. Kim, M. Schwartz et al., Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation, Journal of Cardiovascular Electrophysiology, vol.13, issue.11, pp.1092-1097, 2002.
DOI : 10.1046/j.1540-8167.2002.01092.x

T. Wolber, C. Binggeli, J. Holzmeister, C. Brunckhorst, U. Strobel et al., Wavelet-Based Tachycardia Discrimination in ICDs: Impact of Posture and Electrogram Configuration, Pacing and Clinical Electrophysiology, vol.6, issue.1, pp.1255-1260, 2006.
DOI : 10.1111/j.1540-8159.2005.50011.x

S. Compton, J. Merrill, P. Dorian, J. Cao, D. Zhou et al., Continuous Template Collection and Updating for Electrogram Morphology Discrimination in Implantable Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.3, pp.244-254, 2006.
DOI : 10.1046/j.1540-8167.2002.00432.x

D. Theuns, M. Rivero-ayerza, D. Goedhart, M. Miltenburg, and L. Jordaens, Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates, Europace, vol.10, issue.9, pp.1060-1066, 2008.
DOI : 10.1093/europace/eun194

P. Bouchet, R. Dubois, C. Henry, P. Roussel, and G. Dreyfus, Spatial Projection of Tachycardia Electrograms for Morphology Discrimination in Implantable Cardioverter Defibrillators, IEEE Proc. Computers in Cardiology, vol.36, pp.9-12, 2009.

P. Milpied-sorin and C. Group, Clinical Research Department Parc d'Affaires NOVEOS 4, avenue Réaumur 92140 CLAMART CEDEX FRANCE E-mail address: paola.milpied@sorin.com References

J. Daubert, X. Zareba, D. Cannom, S. Mcnitt, S. Rosero et al., Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II, Journal of the American College of Cardiology, vol.51, issue.14, pp.1357-1365, 2008.
DOI : 10.1016/j.jacc.2007.09.073

C. Swerdlow, M. Brown, K. Lurie, J. Zhang, N. Wood et al., Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet-Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms, Journal of Cardiovascular Electrophysiology, vol.13, issue.5, pp.432-441, 2002.
DOI : 10.1046/j.1540-8167.2002.00432.x

M. Gold, S. Shorofsky, J. Thompson, J. Kim, M. Schwartz et al., Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation, Journal of Cardiovascular Electrophysiology, vol.13, issue.11, pp.1092-1097, 2002.
DOI : 10.1046/j.1540-8167.2002.01092.x

G. Boriani, M. Biffi, L. Frabetti, J. Lattuca, and A. Branzi, Clinical Evaluation of Morphology Discrimination: An Algorithm for Rhythm Discrimination in Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.6, pp.994-1001, 2001.
DOI : 10.1046/j.1460-9592.2001.00994.x

S. Chen, S. Billings, and W. Luo, Orthogonal least squares methods and their application to non-linear system identification, International Journal of Control, vol.10, issue.5, pp.1873-1896, 1989.
DOI : 10.2307/2284566

D. Urbani, P. Roussel-ragot, L. Personnaz, and G. Dreyfus, The Selection of Neural Models of Non-Linear Dynamical Systems by Statistical Tests, Neural Networks for Signal Processing IV, pp.229-237, 1993.

H. Stoppiglia, G. Dreyfus, R. Dubois, and Y. Oussar, Ranking a Random Feature for Variable and Feature Selection, J Mach Learn Res, vol.3, pp.1399-1414, 2003.

V. Vapnik, The Nature of Statistical Learning Theory, 1995.

P. Bouchet-sorin and C. Group, Clinical Research Department Parc d'Affaires NOVEOS 4, avenue Réaumur 92140 CLAMART CEDEX FRANCE E-mail address: paola