Spatial, temporal and wavefront direction characteristics of 12-lead T-wave morphology, Medical & Biological Engineering & Computing, vol.74, issue.5, pp.574-84, 1999. ,
DOI : 10.1007/BF02513351
Arrhythmia detection by dual-chamber implantable cardioverter defibrillatorsA review of current algorithms, Europace, vol.6, issue.4, pp.273-86, 2004. ,
DOI : 10.1016/j.eupc.2004.02.005
The 1+1 Trial: A Prospective Trial of a Dual- Versus a Single-Chamber Implantable Defibrillator in Patients With Slow Ventricular Tachycardias, Circulation, vol.110, issue.9, pp.1022-1031, 2004. ,
DOI : 10.1161/01.CIR.0000140259.16185.7D
Clinical Evaluation of Morphology Discrimination: An Algorithm for Rhythm Discrimination in Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.6, pp.994-1001, 2001. ,
DOI : 10.1046/j.1460-9592.2001.00994.x
Contribution of morphology discrimination algorithm for improving rhythm discrimination in slow and fast ventricular tachycardia zones in dual-chamber implantable cardioverter-defibrillators, Europace, vol.10, issue.8, pp.918-943, 2008. ,
DOI : 10.1093/europace/eun146
Combined Use of Morphology Discrimination, Sudden Onset, and Stability as Discriminating Algorithms in Single Chamber Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.25, issue.9, pp.1357-66, 2002. ,
DOI : 10.1046/j.1460-9592.2002.01357.x
Spatial Projection of Tachycardia Electrograms for Morphology Discrimination in Implantable Cardioverter Defibrillators, IEEE Proc. Computers in Cardiology, vol.36, pp.9-12, 2009. ,
Clinical Evaluation of a Prototype Passive Fixation Dual Chamber Single Pass Lead For Dual Chamber ICD Systems, Pacing and Clinical Electrophysiology, vol.19, issue.1, 1999. ,
DOI : 10.1111/j.1540-8159.1999.tb00326.x
Synchronous AV pacing with a single pervenous electrode, Br Heart J, vol.35, issue.5, p.559, 1973. ,
Orthogonal least squares methods and their application to non-linear system identification, International Journal of Control, vol.10, issue.5, pp.1873-1896, 1989. ,
DOI : 10.2307/2284566
Continuous Template Collection and Updating for Electrogram Morphology Discrimination in Implantable Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.3, pp.244-54, 2006. ,
DOI : 10.1046/j.1540-8167.2002.00432.x
Performance of a new single-chamber ICD algorithm: discrimination of supraventricular and ventricular tachycardia based on vector timing and correlation, Europace, vol.8, issue.12, pp.1057-61, 2006. ,
DOI : 10.1093/europace/eul119
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II, Journal of the American College of Cardiology, vol.51, issue.14, pp.1357-65, 2008. ,
DOI : 10.1016/j.jacc.2007.09.073
An Algorithm for Verifying Biventricular Capture Based on Evoked-Response Morphology, Pacing and Clinical Electrophysiology, vol.23, issue.s1, pp.15-23, 2005. ,
DOI : 10.1111/j.1540-8159.2005.00099.x
Apprentissage Statistique ? Réseaux de neurones, cartes topologiques, machines à vecteurs supports, 2008. ,
T-Wave Morphology Parameters Based on Principal Component Analysis Reproducibility and Dependence on T???Offset Position, Annals of Noninvasive Electrocardiology, vol.23, issue.4, pp.354-63, 2007. ,
DOI : 10.1111/j.1365-2796.2005.01587.x
A New Defibrillator Discrimination Algorithm Utilizing Electrogram Morphology Analysis, Pacing and Clinical Electrophysiology, vol.14, issue.1, pp.179-82, 1999. ,
DOI : 10.1016/S0002-9149(97)00633-4
Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation, Journal of Cardiovascular Electrophysiology, vol.13, issue.11, pp.1092-1099, 2002. ,
DOI : 10.1046/j.1540-8167.2002.01092.x
European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead, Pacing and Clinical Electrophysiology, vol.25, issue.7, pp.1079-86, 2002. ,
DOI : 10.1046/j.1460-9592.2002.01079.x
Independent Component Analysis, 2002. ,
Principal Component Analysis, Second Edition, 2002. ,
Improving SVT Discrimination in Single-Chamber ICDs: A New Electrogram Morphology-Based Algorithm, Journal of Cardiovascular Electrophysiology, vol.103, issue.12, 2006. ,
DOI : 10.1111/j.1540-8159.2000.tb00919.x
Acute and long? term experience with a new single lead for VDD pacing, Eur J Cardiac Pacing Electrophysiol, vol.4, pp.274-82, 1992. ,
Experience and Implantation Techniques with a New Single-Pass Lead VDD Pacing System, Pacing and Clinical Electrophysiology, vol.9, issue.7, pp.927-963, 1990. ,
DOI : 10.1111/j.1540-8159.1990.tb02130.x
Electrogram Configuration and Detection of Supraventricular Tachycardias by a Morphology Discrimination Algorithm in Single Chamber ICDs, Pacing and Clinical Electrophysiology, vol.23, issue.6, pp.555-60, 2005. ,
DOI : 10.1016/S0002-9149(96)00501-2
Morphological Stability of Bipolar and Unipolar Endocardial Electrograms, IEEE Proc. Computers in Cardiology, vol.37, pp.733-736, 2010. ,
VDD(R) Pacing: Short- and Long-Term Stability of Atrial Sensing with a Single Lead System, Pacing and Clinical Electrophysiology, vol.116, issue.4, pp.455-64, 1996. ,
DOI : 10.1111/j.1540-8159.1996.tb06516.x
Dual Chamber Pacing with a Single-Lead DDD Pacing System, Pacing and Clinical Electrophysiology, vol.19, issue.7, pp.1013-1022, 1999. ,
DOI : 10.1111/j.1540-8159.1999.tb00565.x
Chronic Experiences with a Single Lead Dual Chamber Implantable Cardioverter Defibrillator System, Pacing and Clinical Electrophysiology, vol.21, issue.10, p.1937, 2003. ,
DOI : 10.1046/j.1460-9592.2001.00183.x
Inappropriate implantable cardioverter-defibrillator discharges unrelated to supraventricular tachyarrhythmias, Europace, vol.8, issue.10, pp.863-872, 2006. ,
DOI : 10.1093/europace/eul093
URL : http://europace.oxfordjournals.org/cgi/content/short/8/10/863
Atrial Activity Extraction for Atrial Fibrillation Analysis Using Blind Source Separation, IEEE Transactions on Biomedical Engineering, vol.51, issue.7, pp.1176-1186, 2004. ,
DOI : 10.1109/TBME.2004.827272
SYMPOSIUM ON ELECTROCARDIOGRAPHY AND VECTORCARDIOGRAPHY, A.M.A. Archives of Internal Medicine, vol.96, issue.5, pp.574-90, 1955. ,
DOI : 10.1001/archinte.1955.00250160016002
Feasibility of atrial sensing via a free?floating single? pass defibrillation lead for dual?chamber defibrillators, Journal of Interventional Cardiac Electrophysiology, vol.8, issue.3, pp.209-223, 2003. ,
DOI : 10.1023/A:1023921322671
Inappropriate arrhythmia detection in implantable defibrillator therapy due to oversensing of diaphragmatic myopotentials, Journal of Interventional Cardiac Electrophysiology, vol.5, issue.4, pp.487-93, 2001. ,
DOI : 10.1023/A:1013214516002
Cross?Validatory Choice and Assessment of Statistical Predictions, Journal of the Royal Statistical Society. Series B (Methodological), vol.36, issue.2, pp.111-147, 1974. ,
Ranking a random feature for variable and feature selection, JMLR.org, vol.3, pp.1399-1414, 2003. ,
Spatiotemporal QRST cancellation techniques for analysis of atrial fibrillation, IEEE Transactions on Biomedical Engineering, vol.48, issue.1, pp.105-111, 2001. ,
DOI : 10.1109/10.900266
Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet-Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms, Journal of Cardiovascular Electrophysiology, vol.13, issue.5, pp.432-473, 2002. ,
DOI : 10.1046/j.1540-8167.2002.00432.x
Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates, Europace, vol.10, issue.9, pp.1060-1066, 2008. ,
DOI : 10.1093/europace/eun194
Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators, Heart Rhythm, vol.3, issue.11, pp.1332-1340, 2006. ,
DOI : 10.1016/j.hrthm.2006.06.034
The selection of neural models of nonlinear dynamical systems by statistical tests, Proceedings of IEEE Workshop on Neural Networks for Signal Processing, 1994. ,
DOI : 10.1109/NNSP.1994.366044
The Nature of Statistical Learning Theory, 1995. ,
Single-Lead VDD Pacing System, Pacing and Clinical Electrophysiology, vol.11, issue.4, pp.757-66, 1990. ,
DOI : 10.1016/0002-9149(87)91179-9
The vectorcardiogram, American Heart Journal, vol.16, issue.1, pp.14-28, 1938. ,
DOI : 10.1016/S0002-8703(38)90899-3
Wavelet-Based Tachycardia Discrimination in ICDs: Impact of Posture and Electrogram Configuration, Pacing and Clinical Electrophysiology, vol.6, issue.1, pp.1255-60, 2006. ,
DOI : 10.1111/j.1540-8159.2005.50011.x
Statistical Methods in Diagnostic Medicine, 2002. ,
Arrhythmia Discrimination in Implantable Cardioverter Defibrillators using Support Vector Machines applied to a new Representation of Electrograms Stability of bipolar and unipolar endocardial electrograms Arrhythmia classification using spatial projection of tachycardia electrograms, Compterendus de conférences Atrial activity extraction in single?chamber implantable defibrillators, pp.733-736, 2010. ,
Spatial projection of tachycardia electrograms for morphology discrimination in implantable cardioverter defibrillators Dispositif médical actif comprenant des moyens de détection et de filtrage d'artéfacts par analyse du vectogramme cardiaque, Europace IEEE Proc. Computers in Cardiology, vol.12, issue.36, 2009. ,
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II, Journal of the American College of Cardiology, vol.51, issue.14, pp.1357-65, 2008. ,
DOI : 10.1016/j.jacc.2007.09.073
Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet-Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms, Journal of Cardiovascular Electrophysiology, vol.13, issue.5, pp.432-473, 2002. ,
DOI : 10.1046/j.1540-8167.2002.00432.x
Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation, Journal of Cardiovascular Electrophysiology, vol.13, issue.11, pp.1092-1099, 2002. ,
DOI : 10.1046/j.1540-8167.2002.01092.x
Clinical Evaluation of Morphology Discrimination: An Algorithm for Rhythm Discrimination in Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.6, pp.994-1001, 2001. ,
DOI : 10.1046/j.1460-9592.2001.00994.x
Combined use of morphology discrimination, sudden onset, and stability as discriminating algorithms in single chamber cardioverter defibrillators, Pacing Clin Electrophysiol, vol.25, pp.1357-66, 2002. ,
Electrogram Configuration and Detection of Supraventricular Tachycardias by a Morphology Discrimination Algorithm in Single Chamber ICDs, Pacing and Clinical Electrophysiology, vol.23, issue.6, pp.555-60, 2005. ,
DOI : 10.1016/S0002-9149(96)00501-2
Wavelet-Based Tachycardia Discrimination in ICDs: Impact of Posture and Electrogram Configuration, Pacing and Clinical Electrophysiology, vol.6, issue.1, pp.1255-60, 2006. ,
DOI : 10.1111/j.1540-8159.2005.50011.x
Projective Filtering of Time-Aligned ECG Beats, IEEE Transactions on Biomedical Engineering, vol.51, issue.7, pp.1129-1168, 2004. ,
DOI : 10.1109/TBME.2004.826592
Spatial Projection of Tachycardia Electrograms for Morphology Discrimination in Implantable Cardioverter Defibrillators, IEEE Proc. Computers in Cardiology, vol.36, pp.9-12, 2009. ,
Evaluation of morphology discrimination for ventricular tachycardia diagnosis in implantable cardioverter-defibrillators, Heart Rhythm, vol.3, issue.11, pp.1332-1340, 2006. ,
DOI : 10.1016/j.hrthm.2006.06.034
The Nature of Statistical Learning Theory, 1995. ,
Cross-validatory choice and assessment of statistical predictions, J Roy Statist Soc Ser B, vol.36, pp.111-147, 1974. ,
Statistical methods in diagnostic medicine, 2002. ,
Continuous Template Collection and Updating for Electrogram Morphology Discrimination in Implantable Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.3, pp.244-54, 2006. ,
DOI : 10.1046/j.1540-8167.2002.00432.x
Morphology discrimination in implantable cardioverterdefibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates Stability of bipolar and unipolar endocardial electrograms Inappropriate Implantable Cardioverter Defibrillator Shocks in MADIT II, IEEE Proc. Computing in Cardiology, pp.1060-1066, 2008. ,
Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet-Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms, Journal of Cardiovascular Electrophysiology, vol.13, issue.5, pp.432-441, 2002. ,
DOI : 10.1046/j.1540-8167.2002.00432.x
Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation, Journal of Cardiovascular Electrophysiology, vol.13, issue.11, pp.1092-1097, 2002. ,
DOI : 10.1046/j.1540-8167.2002.01092.x
Wavelet-Based Tachycardia Discrimination in ICDs: Impact of Posture and Electrogram Configuration, Pacing and Clinical Electrophysiology, vol.6, issue.1, pp.1255-1260, 2006. ,
DOI : 10.1111/j.1540-8159.2005.50011.x
Continuous Template Collection and Updating for Electrogram Morphology Discrimination in Implantable Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.3, pp.244-254, 2006. ,
DOI : 10.1046/j.1540-8167.2002.00432.x
Morphology discrimination in implantable cardioverter-defibrillators: consistency of template match percentage during atrial tachyarrhythmias at different heart rates, Europace, vol.10, issue.9, pp.1060-1066, 2008. ,
DOI : 10.1093/europace/eun194
Spatial Projection of Tachycardia Electrograms for Morphology Discrimination in Implantable Cardioverter Defibrillators, IEEE Proc. Computers in Cardiology, vol.36, pp.9-12, 2009. ,
Clinical Research Department Parc d'Affaires NOVEOS 4, avenue Réaumur 92140 CLAMART CEDEX FRANCE E-mail address: paola.milpied@sorin.com References ,
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II, Journal of the American College of Cardiology, vol.51, issue.14, pp.1357-1365, 2008. ,
DOI : 10.1016/j.jacc.2007.09.073
Discrimination of Ventricular Tachycardia from Supraventricular Tachycardia by a Downloaded Wavelet-Transform Morphology Algorithm: A Paradigm for Development of Implantable Cardioverter Defibrillator Detection Algorithms, Journal of Cardiovascular Electrophysiology, vol.13, issue.5, pp.432-441, 2002. ,
DOI : 10.1046/j.1540-8167.2002.00432.x
Advanced Rhythm Discrimination for Implantable Cardioverter Defibrillators Using Electrogram Vector Timing and Correlation, Journal of Cardiovascular Electrophysiology, vol.13, issue.11, pp.1092-1097, 2002. ,
DOI : 10.1046/j.1540-8167.2002.01092.x
Clinical Evaluation of Morphology Discrimination: An Algorithm for Rhythm Discrimination in Cardioverter Defibrillators, Pacing and Clinical Electrophysiology, vol.24, issue.6, pp.994-1001, 2001. ,
DOI : 10.1046/j.1460-9592.2001.00994.x
Orthogonal least squares methods and their application to non-linear system identification, International Journal of Control, vol.10, issue.5, pp.1873-1896, 1989. ,
DOI : 10.2307/2284566
The Selection of Neural Models of Non-Linear Dynamical Systems by Statistical Tests, Neural Networks for Signal Processing IV, pp.229-237, 1993. ,
Ranking a Random Feature for Variable and Feature Selection, J Mach Learn Res, vol.3, pp.1399-1414, 2003. ,
The Nature of Statistical Learning Theory, 1995. ,
Clinical Research Department Parc d'Affaires NOVEOS 4, avenue Réaumur 92140 CLAMART CEDEX FRANCE E-mail address: paola ,