D. Royer, E. P. Dieulesaint-]-a, O. V. Sarvazyan, S. D. Rudenko, J. B. Swanson et al., Shear Wave Elasticity Imaging: A New Ultrasonic Technology of Medical Diagnosis The three-dimensional organization of collagen fibrils in the human cornea and sclera, Elastic Waves in Solids I : Free and Guided Propagation, pp.1419-1435, 1991.

J. Coleman, Y. Zeng, J. Yang, K. Huang, Z. Lee et al., Ultrasound Biomicroscopy: High-Frequency Ultrasound Imaging of the Eye at Microscopic Resolution A comparison of biomechanical properties between human and porcine cornea Stress-strain measurements of human and porcine corneas after riboflavin?ultraviolet-A-induced cross-linking Regional elastic performance of the human cornea Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis, Ultrasonic Imaging Radiologic Clinics of North America Journal of Biomechanics Journal of Cataract & Refractive Surgery J. O. Hjortdal Journal of Biomechanics Journal of Cataract & Refractive Surgery, vol.28, issue.31 1, pp.179-188, 1996.

D. A. Luce, Determining in vivo biomechanical properties of the cornea with an ocular response analyzer, Journal of Cataract & Refractive Surgery, vol.31, issue.1, pp.156-162, 2005.
DOI : 10.1016/j.jcrs.2004.10.044

W. J. Dupps, M. V. Netto, S. Herekar, and R. R. Krueger, Surface Wave Elastometry of the Cornea in Porcine and Human Donor Eyes, Journal of Cataract & Refractive Surgery, vol.23, issue.1, pp.66-75, 2007.

B. Finlay, Dynamic mechanical testing of human skin ???in vivo???, Journal of Biomechanics, vol.3, issue.6, pp.557-558, 1970.
DOI : 10.1016/0021-9290(70)90040-0

H. L. Stark, Directional variations in the extensibility of human skin, British Journal of Plastic Surgery, vol.30, issue.2, pp.105-114, 1977.
DOI : 10.1016/0007-1226(77)90001-7

P. G. Agache, C. Monneur, J. L. Leveque, and J. De-rigal, Mechanical properties and Young's modulus of human skin in vivo, Archives of Dermatological Research, vol.6, issue.3, pp.221-232, 1980.
DOI : 10.1007/BF00406415

A. O. Barel, W. Courage, and P. Clarys, Suction method for the measurement of skin mechanical properties: the Cutometer, Handbook of Non-Invasive Methods and the Skin, pp.335-339, 1995.

S. Diridollou, M. Berson, V. Vabre, D. Black, B. Karlsson et al., An In Vivo Method for Measuring the Mechanical Properties of the Skin Using Ultrasound, Ultrasound in Medicine & Biology, vol.24, issue.2, pp.215-224, 1998.
DOI : 10.1016/S0301-5629(97)00237-8

S. Diridollou, F. Patat, F. Gens, L. Vaillant, D. Black et al., In vivo model of the mechanical properties of the human skin under suction, Skin Research and Technology, vol.6, issue.4, pp.214-221, 2000.
DOI : 10.1034/j.1600-0846.2000.006004214.x

C. W. Gunner, W. C. Hutton, and T. E. Burlin, The mechanical properties of skin in vivo???a portable hand-held extensometer, British Journal of Dermatology, vol.13, issue.2, pp.161-163, 1979.
DOI : 10.1111/j.1365-2133.1979.tb05555.x

P. Vescovo, D. Varchon, and P. Humbert, In vivo tensile tests on human skin: the extensometers, Bioengineering of the skin: Skin Biomechanics

Y. Mofid, G. Josse, S. Gahagnon, A. Delalleau, and F. Ossant, Mechanical skin thinning-to-thickening transition observed in vivo through 2D high frequency elastography, Journal of Biomechanics, vol.43, issue.15, pp.2954-2962, 2010.
DOI : 10.1016/j.jbiomech.2010.07.014

J. Gennisson, Le palpeur acoustique: un nouvel outil d'investigation des tissus biologiques, 2003.

J. Ophir, I. Céspedes, H. Ponnekanti, Y. Yazdi, and X. Li, Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues, Ultrasonic Imaging, vol.13, issue.2, pp.111-134, 1991.
DOI : 10.1177/016173469101300201

K. J. Parker, S. R. Huang, R. A. Musulin, and R. M. Lerner, Tissue response to mechanical vibrations for ???sonoelasticity imaging???, Ultrasound in Medicine & Biology, vol.16, issue.3, pp.241-246, 1990.
DOI : 10.1016/0301-5629(90)90003-U

M. Fatemi and J. F. Greenleaf, Vibro-acoustography: An imaging modality based on ultrasound-stimulated acoustic emission, Proceedings of the National Academy of Sciences of the United States of America, pp.6603-6611, 1999.
DOI : 10.1073/pnas.96.12.6603

K. Nightingale, M. S. Soo, R. Nightingale, and G. Trahey, Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility, Ultrasound in Medicine & Biology, vol.28, issue.2, pp.227-262, 2002.
DOI : 10.1016/S0301-5629(01)00499-9

S. Catheline, Interférométrie-speckle ultrasonore: Application à la mesure d'élasticité, 1998.

L. Sandrin, M. Tanter, S. Catheline, and M. Fink, Shear modulus imaging with 2-D transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control2, pp.426-435, 2002.
DOI : 10.1109/58.996560

M. Tanter, J. Bercoff, L. Sandrin, and M. Fink, Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.49, issue.10, pp.1363-1374, 2002.
DOI : 10.1109/TUFFC.2002.1041078

. Meunier, In vivo breast tumor detection using transient elastography, Ultrasound in Medicine & Biology, vol.29, issue.10, pp.1387-1396, 2003.

J. Bercoff, L'imagerie échographique ultrarapide et son application à l'étude de la viscoélasticité du corps humain, 2004.

S. Chen, M. W. Urban, C. Pislaru, R. Kinnick, Y. Zheng et al., Shearwave dispersion ultrasound vibrometry (SDUV) for measuring tissue elasticity and viscosity, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, issue.1, pp.55-62, 2009.
DOI : 10.1109/TUFFC.2009.1005

T. Deffieux, Palpation par force de radiation ultrasonore et échographie ultrarapide : Applications à la caractérisation tissulaire in vivo, 2008.

M. Muller, J. Gennisson, T. Deffieux, M. Tanter, and M. Fink, Quantitative Viscoelasticity Mapping of Human Liver Using Supersonic Shear Imaging: Preliminary In Vivo Feasability Study, Ultrasound in Medicine & Biology, vol.35, issue.2, pp.219-229, 2009.
DOI : 10.1016/j.ultrasmedbio.2008.08.018

.. 'eau, Propagation guidée dans une plaque mince élastique immergée dans l, p.48

.. Elastographie-de-la-cornée-ex-vivo-et-in-vivo-chez-le-porc, 69 4.3.1. Expériences sur des cornées porcines ex vivo, p.72

.. Influence-de-la-tension-du-tissu, 73 4.4.1. Effet de la pression intraoculaire, ., p.77

]. D. Luce-]-t, A. Williamson, . D. Harris, J. Royer, T. Gennisson et al., Determining in vivo biomechanical properties of the cornea with an ocular response analyzer Ocular blood flow measurement On the elasticity of transverse isotropic soft tissues (L) Elastic Waves in Solids I : Free and Guided Propagation Palpation par force de radiation ultrasonore et échographie ultrarapide : Applications à la caractérisation tissulaire in vivo In vivo quantitative mapping of myocardial stiffening and transmural anisotropy during the cardiac cycle Mapping Myocardial Fiber Orientation Using Echocardiography-Based Shear Wave Imaging, Dans les chapitres suivants, nous allons développer des applications potentielles de l'élastographie SSI en ophtalmologie et en dermatologie. 4.7. Références, pp.156-162, 1994.

K. M. Votruba, ]. Meek, and . Langer, Comparative study of fibrillar collagen arrangement in the corneas of primates and other mammals On the anatomy and physiology of the skin: I. The cleavability of the cutis, The Anatomical Record, pp.1542-1550, 1978.

Y. S. Rabinowitz, T. B. Edrington, J. T. Barr, K. Zadnik, L. J. Davis et al., Standardized Rigid Contact Lens Fitting Protocol for Keratoconus INTACS Inserts for Treating Keratoconus Induction of cross-links in corneal tissue Safety of UVA-riboflavin crosslinking of the cornea Collagen cross-linking: Strengthening the unstable cornea Stress-strain measurements of human and porcine corneas after riboflavin?ultraviolet-A-induced cross-linking Riboflavin/ultraviolet-a?induced collagen crosslinking for the treatment of keratoconus, Long-term results of riboflavin ultraviolet A corneal collagen cross-linking for keratoconus in Italy: the Siena eye cross study, pp.297-319, 1996.

D. A. Luce, Determining in vivo biomechanical properties of the cornea with an ocular response analyzer, Journal of Cataract & Refractive Surgery, vol.31, issue.1, pp.156-162, 2005.
DOI : 10.1016/j.jcrs.2004.10.044

Y. Goldich, Y. Barkana, Y. Morad, M. Hartstein, M. Avni et al., Can We Measure Corneal Biomechanical Changes After Collagen Cross-Linking in Eyes With Keratoconus?-A Pilot Study, Cornea, vol.28, issue.5, pp.498-502, 2009.
DOI : 10.1097/ICO.0b013e318190734d

C. Faber, E. Scherfig, and J. U. Prause, Corneal Thickness in Pigs Measured by Ultrasound Pachymetry In Vivo, Scandinavian Journal of Laboratory Animal Science, vol.35, issue.1, pp.39-43, 2008.

S. Baiocchi, C. Mazotta, D. Cerretani, T. Caporossi, and A. Caporossi, Corneal crosslinking: Riboflavin concentration in corneal stroma exposed with and without epithelium, Journal of Cataract & Refractive Surgery, vol.35, issue.5, pp.893-899, 2009.
DOI : 10.1016/j.jcrs.2009.01.009

L. 'étude-est-réalisée and . Au-centre, L'objectif de l'étude est d'investiguer le potentiel de l'élastographie comme outil de diagnostic différentiel des tumeurs cutanées. Nous proposons l'élastographie SSI pour mesurer les variations d'élasticité entre la zone pathologique et la zone saine, et pour évaluer les dimensions des tumeurs (en particulier l'extension en profondeur), Le protocole a été approuvé par le Comité de Protection des Personnes Est-II (CPP) et par l'Agence Française de Sécurité Sanitaire des Produits de Santé (AFSSAPS)

. J. Bailey-]-h, J. Wulf, T. Sandby-møller, R. Kobayasi, E. C. Gniadecki et al., la recherche -sujet affilié à un régime de sécurité sociale Les critères d'exclusion sont les suivants : -sujet en période d'exclusion du fait d'un autre essai clinique 6.5. Références [1] A Molecular mechanisms of ageing in connective tissues Skin aging and natural photoprotection The role of collagen and elastin in aged skin: an image processing approach Molecular aspects of skin ageing Torsional elasticity of human skin in vivo Physiopathological variations in the mechanical properties of skin, de taille inférieure à 15 mm relevant d'indication d'exérèse -sujet présentant une lésion cutanée bénigne (naevus, kystes, etc?) -sujet ayant donné son consentement éclairé pour Influence of Ageing on the in Vivo Extensibility of Human Skin at a Low Stress Pflügers Archives, pp.735-55, 1973.