CITY DRAIN -An open source approach for simulation of integrated urban drainage systems. Environmental Modelling and Software, article in press, pp.1-12, 2006. ,
Storm water quality modelling, an ambitious objective? Water Science and Technology, pp.205-213, 1998. ,
Bilan et intérêt opérationnel du programme de recherche de l'observatoire des polluants urbains (Opur), pp.122-128, 2006. ,
Dépollution des effluents urbains de temps de pluie en bassins de stockage décantation, TSM, vol.12, pp.70-86, 2003. ,
Caractérisation du fonctionnement d'un ouvrage de stockage décantation des eaux pluviales urbaines : cas de la galerie de stockage décantation Tolbiac-Masséna, Mémoire de stage de master effectué au Cereve, 2008. ,
Sewer solids -20 years of investigation, Water Science and Technology, vol.52, issue.3, pp.73-84, 2005. ,
The management of sediment in combined sewers, Urban Water, vol.2, issue.4, pp.263-275, 2000. ,
DOI : 10.1016/S1462-0758(01)00010-3
Turbidity monitoring in sewage, 10th International Conference on Urban Drainage, 2005. ,
Mesure en continu de la turbidité sur un réseau séparatif d'eaux usées : mise en oeuvre et premiers résultats, pp.121-128, 2006. ,
DOI : 10.1051/lhb:200604021
Processing sewage turbidity and conductivity recorded in sewage for assessing sanitary water and infltration/inflow discharges, 11th International Conference on Urban Drainage -Edinburgh, 2008. ,
Disons Douze ans. Rapport du Service départemental d'assainissement (Seine-Saint-Denis), 1984. ,
Validation des donn??es hydrom??triques par des techniques univari??es de filtrage, Canadian Journal of Civil Engineering, vol.23, issue.4, pp.872-892, 1996. ,
DOI : 10.1139/l96-895
TSS concentration in sewers estimated from turbidity measurements by means of linear regression accounting for uncertainties in both variables, Water Science and Technology, vol.50, issue.11, pp.81-88, 2004. ,
Distribution of pollutant mass vs volume in stormwater discharges and the first flush phenomenon, Water Research, vol.32, issue.8, pp.2341-2356, 1998. ,
DOI : 10.1016/S0043-1354(97)00420-X
URL : https://hal.archives-ouvertes.fr/hal-00779532
Dictionnaire pratique de la métrologie -Mesure, essai et calculs d'incertitudes AFNOR, 2006. ,
Ouvrages de stockage et de décantation des eaux pluviales du quartier Paris Rive Gauche (13ème arrondissement), TSM, vol.12, pp.107-109, 2003. ,
Les bassins de stockage-décantation en Seine-Saint-Denis, pp.93-95, 2003. ,
Urban storm water in Germany, In Urban Drainage. ASCE, 2002. ,
Integrating simulation models with a view to optimal control of urban wastewater systems, Environmental Modelling & Software, vol.20, issue.4, pp.415-426, 2005. ,
DOI : 10.1016/j.envsoft.2004.02.003
Simulation of the operation of detention tanks, Water Research, vol.40, issue.1, pp.83-90, 2006. ,
DOI : 10.1016/j.watres.2005.10.025
Regulators'setup with application to the Roma-Cecchignola combined sewer system, pp.235-242, 2000. ,
Design and RTC of tanks for the control pollution due to CSOs, 10th International Conference on Urban Drainage, 2005. ,
Les séries temporelles -Cours du module XML et Data Mining, 2006. ,
Solides des rejets pluvieux urbains : caractérisation et traitabilité, p.413, 1992. ,
The transfer of solids in combined sewer networks, Water Science and Technology, vol.31, issue.7, pp.31-95, 1995. ,
DOI : 10.1016/0273-1223(95)00327-J
URL : https://hal.archives-ouvertes.fr/hal-00779544
Gestion en temps réel des réseaux d'assainissement : bilan de 25 ans d'expériences en France et dans le monde, pp.23-34, 2005. ,
Encyclopédie de l'Hydrologie urbaine et de l'assainissement, Techniques & Documentation, 1997. ,
A MONTE CARLO TEST OF LOAD CALCULATION METHODS, LAKE TAHOE BASIN, CALIFORNIA-NEVADA, Journal of the American Water Resources Association, vol.29, issue.4, pp.719-730, 2002. ,
DOI : 10.1002/esp.3290120111
Practical perspective on real-time control, Water Quality Research Journal of Canada, vol.39, pp.466-478, 2004. ,
Application of Real Time Control for CSO and SSO Abatement: Lessons Learned from 6 Years of Operation in Quebec City, Impacts of Global Climate Change, 2005. ,
DOI : 10.1061/40792(173)158
Neuronal-optimal control algorithm for real-time regulation of in-line storage in combined sewer systems. Environmental Modelling and Software, article in press, pp.1-13, 2006. ,
Théorie et traitement des signaux, Ecole polytechnique fédérale de Lausanne -Traité d'électricité, 1998. ,
Evaluation of Water Quality Factors in Storm Runoff from Paved Areas, Journal of Environmental Engineering, vol.124, issue.9, pp.869-879, 1998. ,
DOI : 10.1061/(ASCE)0733-9372(1998)124:9(869)
Contaminant loads of CSOs at the wasterwater treatement plant of a city in NW Spain, pp.291-299, 2002. ,
Ideal spatial adaptation by wavelet shrinkage, Biometrika, vol.81, issue.3, pp.425-455, 1994. ,
DOI : 10.1093/biomet/81.3.425
PREDICTIVE REAL TIME CONTROL OF SURCHARGED INTERCEPTORS: IMPACT OF SEVERAL CONTROL PARAMETERS, Journal of the American Water Resources Association, vol.36, issue.8, pp.125-135, 2003. ,
DOI : 10.1145/355769.355773
Real-Time Control for Two Communities - Technical and Administrational Aspects, Global Solutions for Urban Drainage, 2002. ,
DOI : 10.1061/40644(2002)320
Fiabilité et précision de la mesure en continu de la turbidité en réseaux d'assainissement, 2005. ,
Integrated modelling for analysis and optimisation of wastewater systems ??? the Odenthal case, Urban Water, vol.4, issue.1, pp.63-71, 2002. ,
DOI : 10.1016/S1462-0758(01)00060-7
CSO detention tanks in Barcelona : real time control design and operation, 10th International Conference on Urban Drainage, 2005. ,
Modelling oxygen deficits in the Seine River downstream of combined sewer overflows, Ecological Modelling, vol.173, issue.2-3, pp.177-196, 2004. ,
DOI : 10.1016/j.ecolmodel.2003.08.019
Wet-weather flow in the urban watershed, Technology and management, 2003. ,
Statistical evaluation and optimisation of stormwater quality monitoring programmes, Water Science & Technology, vol.56, issue.12, pp.1-9, 2007. ,
DOI : 10.2166/wst.2007.744
Development and implementation of a real-time control strategy for the sewer system of the city of Vienna, Water Science and Technology, vol.52, issue.5, pp.187-194, 2005. ,
Variabilité spatiale des caractéristiques des polluants transitant par temps de pluie dans le réseau d'assainissement unitaire parisien, TSM, vol.11, pp.35-49, 2006. ,
DOI : 10.1051/lhb:2007051
Variabilité spatiale des caractéristiques des polluants transitant par temps sec dans le réseau d'assainissement unitaire parisien, TSM, vol.11, pp.23-34, 2006. ,
DOI : 10.1051/lhb:2007051
Methods and Algorithms for Robust Filtering, COMPSTAT 2004 -Section Robustness, 2004. ,
DOI : 10.1007/978-3-7908-2656-2_12
Prévention et diminution des inondations urbaines : « émergence des solutions intégrées, Novatech 2004, techniques et stratégies durables pour la gestion des eaux urbaines par temps de pluie, 2004. ,
Integrated sewerage system methodology and modelling : from Grand-Couronne to Saint-Malo, Conference on Sewer Processes and Networks, pp.287-294, 2002. ,
Pollution modelling on the site of Saint- Malo: an interesting tool for sewer systems optimization, Novatech 2004, techniques et stratégies durables pour la gestion des eaux urbaines par temps de pluie, 2004. ,
Despiking Acoustic Doppler Velocimeter Data, Journal of Hydraulic Engineering, vol.128, issue.1, pp.117-126, 2002. ,
DOI : 10.1061/(ASCE)0733-9429(2002)128:1(117)
Operational use of urban drainage pollutant flux models -results from a french survey, International Conference of Sewer Operation and Maintenance SOM, pp.26-28, 2002. ,
Contribution of different sources to the pollution of wet weather flows in combined sewers, Water Research, vol.35, issue.2, pp.521-523, 2001. ,
DOI : 10.1016/S0043-1354(00)00261-X
URL : https://hal.archives-ouvertes.fr/hal-00711820
Origins and characteristics of urban wet weather pollution in combined sewer systems: the experimental urban catchment ??????Le Marais?????? in Paris, Water Science and Technology, vol.37, issue.1, pp.35-43, 1998. ,
DOI : 10.1016/S0273-1223(97)00753-1
Continuous monitoring in sewer networks an approach for quantification of pollution loads from CSOs into surface water bodies, Water Science and Technology, issue.12, pp.52-215, 2005. ,
Integrated control strategies based on online measurements in sewer systems and wastewater treatment plants, Conference on Sewer Processes and Networks, pp.295-301, 2002. ,
Investigations of the dynamic behaviour of the composition of combined sewage using on-line analyzers, Water Science and Technology, vol.45, pp.77-83, 2002. ,
Investigations of the dynamic behaviour of the composition of combined sewage using on-line analyzers, Water Science and Technology, vol.45, pp.4-5, 2002. ,
On Monitoring of Turbidity in Sewers, Global Solutions for Urban Drainage, 2001. ,
DOI : 10.1061/40644(2002)211
On Monitoring of Turbidity in Sewers, Global Solutions for Urban Drainage, 2002. ,
DOI : 10.1061/40644(2002)211
Online UV VIS measurements "the basis for future pollution based sewer real time control in Linz, Sewer Operation and Maintenance SOM, 2006. ,
The diversity of sewer sediments and the consequences for sewer flow quality modelling, Water Science and Technology, vol.33, issue.9, pp.207-214, 1996. ,
DOI : 10.1016/0273-1223(96)00388-5
Le bassin de stockage et de dépollution de la Grenouillère (communauté urbaine de bordeaux), pp.89-92, 2003. ,
Incertitudes sur un mesurande défini comme une valeur intégrée sur une fenêtre temporelle d'un signal continu discrétisé en fonction du temps -Application aux mesures hydrologiques in situ, pp.82-91, 2009. ,
Reproducibility and uncertainty of wastewater turbidity measurements, Water Science & Technology, vol.57, issue.10, pp.57-1667, 2007. ,
DOI : 10.2166/wst.2008.292
URL : https://hal.archives-ouvertes.fr/hal-00761851
General assessment of potential CSO reduction by means of real time control, Water Science and Technology, vol.32, issue.1, pp.249-257, 1995. ,
DOI : 10.1016/0273-1223(95)00562-2
Variabilité spatiale des caractéristiques et des origines des polluants de temps de pluie dans le réseau d'assainissement unitaire parisien, 2006. ,
Dynamique de transfert de l'eau et des polluants par temps sec et par temps de pluie dans le réseau d'assainissement unitaire parisien, TSM, vol.11, pp.73-85, 2006. ,
A New Approach to Linear Filtering and Prediction Problems, Journal of Basic Engineering, vol.82, issue.1, pp.34-45, 1960. ,
DOI : 10.1115/1.3662552
New Results in Linear Filtering and Prediction Theory, Journal of Basic Engineering, vol.83, issue.1, pp.95-107, 1961. ,
DOI : 10.1115/1.3658902
Stormwater quality modelling in combined sewers: calibration and uncertainty analysis, Water Science and Technology, vol.52, issue.3, pp.63-71, 2005. ,
Pollution based real time control of a combined sewer overflow structure, 10th International Conference on Urban Drainage, 2005. ,
Contribution of different sources to pollutant loads in combined sewers, Proceedings of the 4th International Conference on Urban Drainage, 1987. ,
Gestion intégrée du système d'assainissement du Rosenmeer -Mémoire de fin d'étude, ENGEES, 2007. ,
Am??lioration potentielle de la gestion des effluents de temps de pluie gr??ce ?? des mesures de turbidit??, Techniques Sciences M??thodes, issue.7/8, 2009. ,
DOI : 10.1051/tsm/200907050
Assessment of annual pollutant loads in combined sewers from continuous turbidity measurements: Sensitivity to calibration data, Water Research, vol.43, issue.8, pp.2179-2190, 2009. ,
DOI : 10.1016/j.watres.2009.02.017
URL : https://hal.archives-ouvertes.fr/hal-00451080
Potential of turbidity monitoring for real time control of pollutant discharge in sewers during rainfall events, Water Science & Technology, vol.59, issue.8, pp.59-1471, 2009. ,
DOI : 10.2166/wst.2009.169
URL : https://hal.archives-ouvertes.fr/hal-00451089
Suspended solids transport: an analysis based on turbidity measurements and event based fully calibrated hydrodynamic models, Water Science and Technology, vol.52, issue.3, pp.93-101, 2005. ,
Is combined sewer overflow spill frequency/volume a good indicator of receiving water quality impact?, Urban Water, vol.4, issue.2, pp.181-189, 2002. ,
DOI : 10.1016/S1462-0758(02)00013-4
Turbidity dynamics during spring storm events in an urban headwater river system: The Upper Tame, West Midlands, UK, Science of The Total Environment, vol.360, issue.1-3, pp.109-126, 2006. ,
DOI : 10.1016/j.scitotenv.2005.08.032
Une introduction à l'économétrie des séries temporelles, 1998. ,
Assessment of efficient sampling designs for urban stormwater monitoring, Water Research, vol.36, issue.6, pp.1556-1564, 2002. ,
DOI : 10.1016/S0043-1354(01)00353-0
Etat de l'art sur la gestion en temps réel des réseaux d'assainissement -étude bibliographique et comptes-rendus de visites, 2004. ,
Machine learning in real-time control of water systems, Urban Water, vol.4, issue.3, pp.283-289, 2002. ,
DOI : 10.1016/S1462-0758(02)00023-7
Adaptation of a new online probe for qualitative measurement to combined sewer systems, In Urban Drainage. ASCE, 2002. ,
Analyse des séries temporelles et prévisions -la méthode Box et Jenkins, Annales des Ponts et Chaussées, pp.6-28, 1978. ,
Un an de mesure des flux de Mati??res En Suspension (MES) et de Carbone sur une rivi??re alpine: l'Is??re, La Houille Blanche, issue.5, pp.64-66, 2008. ,
DOI : 10.1051/lhb:2008056
Relations entre caractéristiques de la pollution particulaire et paramètres optiques dans les eaux résiduaires urbaines, Thèse de doctorat -Institut National Polytechnique de Lorraine, Génie des Procédés, 2000. ,
Turbidity-based monitoring of particle concentrations and flocculant requirement in wastewater pre-treatment, Water Science and Technology, issue.11, pp.50-173, 2004. ,
Improved interception of combined sewage in the trondheim-h0vringen wastewater system, Water Science and Technology, vol.39, issue.2, pp.159-168, 1999. ,
DOI : 10.1016/S0273-1223(99)00020-7
Estimating suspended sediment concentrations from turbidity measurements and the calibration problem, Hydrological Processes, vol.111, issue.12, pp.1819-1830, 2008. ,
DOI : 10.1002/hyp.6763
Use of continuous turbidity sensor in the prediction of fine sediment transport in the turbidity maximum of the Trent Estuary, UK, Estuarine, Coastal and Shelf Science, vol.58, issue.3, pp.645-652, 2003. ,
DOI : 10.1016/S0272-7714(03)00176-8
Trendoriented sampling strategy and estimation of soluble reactive phosphorus loads in streams, Water Resources Research, vol.41, issue.1, pp.1020-1021, 2005. ,
Modélisation de la qualité des rejets urbains de temps de pluie : sensibilité aux données expérimentales et adéquation aux besoins opérationnels, Thèse de doctorat - Institut des sciences appliquées de Lyon, 2005. ,
Sensitivity of stormwater quality models to experimental data used for calibration, pp.68-74, 2005. ,
Sensitivity to experimental data of pollutant site mean concentration in stormwater runoff, Water Science and Technology, vol.51, issue.2, pp.155-162, 2005. ,
Qualité de l'eau -Détermination de la turbidité, 2000. ,
) measurement of quality parameters in sewer systems, Conference on Sewer Processes and Networks, pp.303-310, 2002. ,
The impact of a convectional summer rainfall event on river flow and fine sediment transport in a highly urbanised catchment, Science of the Total Environment, vol.314, pp.495-512, 2003. ,
Applied time series analysis, 1978. ,
Advanced real time control of a combined sewer system, Water Science and Technology, vol.37, issue.1, pp.319-326, 1998. ,
DOI : 10.1016/S0273-1223(97)00784-1
Fault detection on a sewer network by a combination of a Kalman filter and a binary sequential probability ratio test, Journal of Hydrology, vol.230, issue.3-4, pp.258-268, 2000. ,
DOI : 10.1016/S0022-1694(00)00213-4
URL : https://hal.archives-ouvertes.fr/emse-01085953
Gestion en temps réel des bassins de retenue, pp.98-101, 2003. ,
Global optimal real-time control of the Quebec urban drainage system, Environmental Modelling & Software, vol.20, issue.4, pp.401-413, 2005. ,
DOI : 10.1016/j.envsoft.2004.02.009
Reliability and robustnes in real-time control applications, 2002. ,
Integrated approach for protection of an urban catchment area, Desalination, vol.188, issue.1-3, pp.51-59, 2006. ,
DOI : 10.1016/j.desal.2005.04.101
Genetic algorithms in real time control applied to minimize transient pollution from urban wastewater systems, Water Research, vol.33, issue.5, pp.1265-1277, 1999. ,
DOI : 10.1016/S0043-1354(98)00304-2
Monte Carlo studies of sampling strategies for estimating tributary loads, Water Resources Research, vol.109, issue.10, pp.1939-1948, 1987. ,
DOI : 10.1029/WR023i010p01939
Continuous measurement of pollution due to urban effluents under wet conditions using optical systems, Water Science and Technology, vol.32, issue.1, pp.241-247, 1995. ,
DOI : 10.1016/0273-1223(95)00561-Z
Accuracy and reproducibility of turbidity measurements in urban waste water, pp.129-135, 2006. ,
URL : https://hal.archives-ouvertes.fr/hal-00711641
Evaluation de l'incertitude des courbes d'étalonnage par la méthode de Monte Carlo. Application à la turbidimétrie, pp.33-43, 2008. ,
Mesurage de la turbidit?? sur ??chantillons : application aux eaux r??siduaires urbaines, Techniques Sciences et Méthodes, pp.61-74, 2008. ,
DOI : 10.1051/tsm/200804061
Self-monitoring of water quality in sewer systems using absorbance of ultraviolet and visible light, Water Science and Technology, vol.44, issue.2-3, pp.269-276, 2001. ,
Dimensionnement d'ouvrages de traitement par décantation des rejets urbains de temps de pluie -Combinaison d'ouvrages de stockagedécantation et de, 1996. ,
Urban discharges during wet weather: What volumes have to be treated?, Water Science and Technology, vol.32, issue.1, pp.225-232, 1995. ,
DOI : 10.1016/0273-1223(95)00559-6
URL : https://hal.archives-ouvertes.fr/hal-00779543
PASST -Die Planungshilfe für Abflusssteuerung in Kanalnetzen, WorkshopInnovationen in der Abwasserableitung und Abwassersteuerung, 2002. ,
The use of turbidity measurements for sewer sediment monitoring, 2002. ,
Integrated Sewage Management-Development of a global Real Time Control for three interconnected Subcatchments of the Berlin Drainage System (gestion intégrée de l'assainissementdéveloppement d'un système global de gestion en temps réel appliqué à trois bassins versants du réseau de Berlin), Novatech 2004, techniques et stratégies durables pour la gestion des eaux urbaines par temps de pluie, 2004. ,
Suitable integrated modelling -based on simplified models, 6th international conference on urban drainage modelling -UDM'04, pp.355-365, 2004. ,
A general algorithm for the development of control algorithm for RTC of sewer systems, 10th International Conference on Urban Drainage, 2005. ,
Parameter optimisation of real-time control strategies for urban wastewater systems, Water Science and Technology, vol.43, issue.7, pp.139-146, 2001. ,
) Modelling, simulation and control of urban wastewater systems, 2002. ,
DOI : 10.1007/978-1-4471-0157-4
Real time control of urban wastewater systems???where do we stand today?, Journal of Hydrology, vol.299, issue.3-4, pp.335-348, 2004. ,
DOI : 10.1016/S0022-1694(04)00375-0
A guideline document for sewer system real time control, Sewer Operation and Maintenance SOM, 2006. ,
Feasibility of Using a Turbidimeter to Quantify Suspended Solids Concentration in a Tidal Saltmarsh Creek, Estuarine, Coastal and Shelf Science, vol.46, issue.3, pp.383-391, 1998. ,
DOI : 10.1006/ecss.1997.0284
Suspended Solids flux between slat mars hand adjacent bay: a long term continuous measurement Results of the Nationwide Urban Runoff Program (NURP), -Final Report, National Technical Information Service (NTIS), Accession Number, pp.84-185552, 1983. ,
Modelling and real-time control of the integrated urban wastewater system, Environmental Modelling & Software, vol.20, issue.4, pp.427-442, 2005. ,
DOI : 10.1016/j.envsoft.2004.02.004
Field Data on Time and Space Scales of Transport Processes in Sewer Systems, Global Solutions for Urban Drainage, 2002. ,
DOI : 10.1061/40644(2002)293
Monitoring and preliminary interpretation of in-river turbidity and remote sensed imagery for suspended sediment transport studies in the Humber catchment, Science of The Total Environment, vol.194, issue.195, pp.263-283, 1997. ,
DOI : 10.1016/S0048-9697(96)05370-3
Load estimation methodologies for British rivers and their relevance to the LOIS RACS(R) programme. The science of the Total Environment, pp.379-389, 0194. ,
Pollution based real time control strategies for combined sewer systems, Water Science and Technology, vol.36, issue.8-9, pp.8-9, 1997. ,
DOI : 10.1016/S0273-1223(97)00577-5
Real-time control in combined sewer systems in Germany??????some case studies, Urban Water, vol.4, issue.4, pp.347-354, 2002. ,
DOI : 10.1016/S1462-0758(02)00031-6
Least-squares fitting of a straight line, Canadian Journal of Physics, vol.46, issue.16, pp.1845-1847, 1968. ,
DOI : 10.1139/p68-523
LEAST-SQUARES FITTING OF A STRAIGHT LINE, Canadian Journal of Physics, vol.44, issue.5, pp.1079-1086, 1966. ,
DOI : 10.1139/p66-090
Quelles sont les capacités de la ou des STEP (en m 3 /jour, en m 3 /h) ? 14. Quel est le débit de temps sec moyen en entrée de STEP ,
Quels paramètres sont pris en compte (MES, DCO?) pour les objectifs relatifs à la pollution ?, p.34 ,
Existe-il une gestion cordonnée entre les différents ouvrages du réseau (si oui veuillez compléter la partie 5) ? ,
the Seine-Normandy Water Agency (AESN), the Seine-Saint-Denis Departmental Council (Water and Sewage Services Department, i.e. DEA 93), the Val-de-Marne Departmental Council (Water and Sewage Services Department i.e. DSEA 94), the Ile-de-France (Paris) Regional Council (CRIF), and GEMCEA (Organisation for Assessment and Continuous Measurements in Water and Sewer Systems) for their much appreciated financial support, We also highly appreciate the contributions of G. Ruban (LCPC) and the Nantes Metropolitan Council for collecting and sharing data from the CB and SM sites ,
Sewer solidsd20 years of investigation, Water Science and Technology, vol.52, issue.3, pp.73-84, 2005. ,
The transfer of solids in combined sewer networks, Water Science and Technology, vol.31, issue.7, pp.95-105, 1995. ,
DOI : 10.1016/0273-1223(95)00327-J
URL : https://hal.archives-ouvertes.fr/hal-00779544
A MONTE CARLO TEST OF LOAD CALCULATION METHODS, LAKE TAHOE BASIN, CALIFORNIA-NEVADA, Journal of the American Water Resources Association, vol.29, issue.4, pp.719-730, 2002. ,
DOI : 10.1002/esp.3290120111
Evaluation of Water Quality Factors in Storm Runoff from Paved Areas, Journal of Environmental Engineering, vol.124, issue.9, pp.869-879, 1998. ,
DOI : 10.1061/(ASCE)0733-9372(1998)124:9(869)
Contaminant loads of CSOs at the wastewater treatment plant of a city in NW Spain, Urban Water, vol.4, issue.3, pp.291-299, 2002. ,
DOI : 10.1016/S1462-0758(02)00020-1
Modelling oxygen deficits in the Seine River downstream of combined sewer overflows, Ecological Modelling, vol.173, issue.2-3, pp.177-196, 2004. ,
DOI : 10.1016/j.ecolmodel.2003.08.019
Statistical evaluation and optimisation of stormwater quality monitoring programmes, Water Science & Technology, vol.56, issue.12, pp.1-9, 2007. ,
DOI : 10.2166/wst.2007.744
Contribution of different sources to the pollution of wet weather flows in combined sewers, Water Research, vol.35, issue.2, pp.521-523, 2001. ,
DOI : 10.1016/S0043-1354(00)00261-X
URL : https://hal.archives-ouvertes.fr/hal-00711820
Continuous monitoring in sewer networks an approach for quantification of pollution loads from CSOs into surface water bodies, Water Science and Technology, vol.52, issue.12, pp.215-223, 2005. ,
Investigations of the dynamic behaviour of the composition of combined sewage using on-line analyzers, Water Science and Technology, vol.45, pp.4-5, 2002. ,
Incertitudes sur un mesurande dé fini comme une valeur inté gré e sur une fenê tre temporelle d'un signal continu discré tisé en fonction du temps. (Uncertainty on a measurement defined as an integrated value on a time window of a continuous timediscretised signal) In: ''Hydrological measurements and uncertaintiesd gaging and water quality, 2008. ,
Reproducibility and uncertainty of wastewater turbidity measurements, Water Science & Technology, vol.57, issue.10, pp.1667-1673, 2007. ,
DOI : 10.2166/wst.2008.292
URL : https://hal.archives-ouvertes.fr/hal-00761851
Suspended solids transport: an analysis based on turbidity measurements and event based fully calibrated hydrodynamic models, Water Science and Technology, vol.52, issue.3, pp.93-101, 2005. ,
Turbidimetry and Nephelometry, Encyclopedia of Analytical Science, pp.343-351, 2005. ,
Assessment of efficient sampling designs for urban stormwater monitoring, Water Research, vol.36, issue.6, pp.1556-1564, 2002. ,
DOI : 10.1016/S0043-1354(01)00353-0
Turbidity-based monitoring of particle concentrations and flocculant requirement in wastewater pre-treatment, Water Science and Technology, vol.50, issue.11, pp.173-178, 2004. ,
Estimating suspended sediment concentrations from turbidity measurements and the calibration problem, Hydrological Processes, vol.111, issue.12, pp.1819-1830, 2008. ,
DOI : 10.1002/hyp.6763
Trend-oriented sampling strategy and estimation of soluble reactive phosphorus loads in streams, Water Resources Research, vol.13, issue.1, pp.1020-1021, 2005. ,
DOI : 10.1029/2004WR003539
Modé lisation de la qualité des rejets urbains de temps de pluie: sensibilité aux donné es expé rimentales et adé quation aux besoins opé rationnels (Modelling of urban wet weather overflows quality: sensitivity to experimental data and adequacy to operational needs, Institut des sciences appliqué es de Lyon, 2005. ,
Sensitivity to experimental data of pollutant site mean concentration in stormwater runoff, Water Science and Technology, vol.51, issue.2, pp.155-162, 2005. ,
The impact of a convectional summer rainfall event on river flow and fine sediment transport in a highly urbanised catchment, Science of the Total Environment, vol.314, pp.495-512, 2003. ,
Monte Carlo studies of sampling strategies for estimating tributary loads, Water Resources Research, vol.109, issue.10, pp.1939-1948, 1987. ,
DOI : 10.1029/WR023i010p01939
Self-monitoring of water quality in sewer systems using absorbance of ultraviolet and visible light, Water Science and Technology, vol.44, issue.2-3, pp.269-276, 2001. ,
Feasibility of Using a Turbidimeter to Quantify Suspended Solids Concentration in a Tidal Saltmarsh Creek, Estuarine, Coastal and Shelf Science, vol.46, issue.3, pp.383-391, 1998. ,
DOI : 10.1006/ecss.1997.0284
Suspended Solids Flux Between Salt Marsh and Adjacent Bay: A Long-term Continuous Measurement, Estuarine, Coastal and Shelf Science, vol.49, issue.1, pp.61-81, 1999. ,
DOI : 10.1006/ecss.1999.0486
Monitoring and preliminary interpretation of in-river turbidity and remote sensed imagery for suspended sediment transport studies in the Humber catchment, Science of The Total Environment, vol.194, issue.195, pp.263-283, 1997. ,
DOI : 10.1016/S0048-9697(96)05370-3
Load estimation methodologies for British rivers and their relevance to the LOIS RACS(R) programme. The Science of the Total Environment, pp.379-389, 0194. ,
EDirective of the European Parliament and the Council of Oct. 2000 establishing a framework for Community action in the field of water policy. Official Journal of the European Communities from 22, WFD, vol.60601272, issue.327, 2000. ,
Distribution of pollutant mass vs volume in stormwater discharges and the first flush phenomenon, Water Research, vol.32, issue.8, pp.2341-2356, 1998. ,
DOI : 10.1016/S0043-1354(97)00420-X
URL : https://hal.archives-ouvertes.fr/hal-00779532
The transfer of solids in combined sewer networks, Water Science and Technology, vol.31, issue.7, pp.31-95, 1995. ,
DOI : 10.1016/0273-1223(95)00327-J
URL : https://hal.archives-ouvertes.fr/hal-00779544
Evaluation of Water Quality Factors in Storm Runoff from Paved Areas, Journal of Environmental Engineering, vol.124, issue.9, pp.869-879, 1998. ,
DOI : 10.1061/(ASCE)0733-9372(1998)124:9(869)
Modelling oxygen deficits in the Seine River downstream of combined sewer overflows, Ecological Modelling, vol.173, issue.2-3, pp.177-196, 2004. ,
DOI : 10.1016/j.ecolmodel.2003.08.019
Statistical evaluation and optimisation of stormwater quality monitoring programmes, Water Science & Technology, vol.56, issue.12, pp.1-9, 2007. ,
DOI : 10.2166/wst.2007.744
Pollution modelling on the site of Saint-Malo: an interesting tool for sewer systems optimization, techniques et straté gies durables pour la gestion des eaux urbaines par temps de pluie, Fifth International Conference Novatech, 2004. ,
Contribution of different sources to the pollution of wet weather flows in combined sewers, Water Research, vol.35, issue.2, pp.521-523, 2001. ,
DOI : 10.1016/S0043-1354(00)00261-X
URL : https://hal.archives-ouvertes.fr/hal-00711820
Integrated control strategies based on online measurements in sewer systems and wastewater treatment plants, Conference on Sewer Processes and Networks, pp.295-301, 2002. ,
Investigations of the dynamic behaviour of the composition of combined sewage using on-line analyzers, Water Sci. Technol, vol.45, pp.4-5, 2002. ,
On Monitoring of Turbidity in Sewers, Global Solutions for Urban Drainage, pp.8-13, 2002. ,
DOI : 10.1061/40644(2002)211
Reproducibility and uncertainty of wastewater turbidity measurements, Water Science & Technology, vol.57, issue.10, pp.1667-1673, 2007. ,
DOI : 10.2166/wst.2008.292
URL : https://hal.archives-ouvertes.fr/hal-00761851
Stormwater quality modelling in combined sewers: calibration and uncertainty analysis, Water Sci. Technol, vol.52, issue.3, pp.63-71, 2005. ,
Pollution based real time control of a combined sewer overflow structure, the Tenth International Conference on Urban Drainage, 2005. ,
Suspended solids transport: an analysis based on turbidity measurements and event based fully calibrated hydrodynamic models, Water Sci. Technol, vol.52, issue.3, pp.93-101, 2005. ,
Turbidimetry and nephelometry (eds) Encyclopedia of Analytical Science, pp.343-351, 2005. ,
Relations entre caracté ristiques de la pollution particulaire et paramè tres optiques dans les eaux ré siduaires urbaines. (Relationship between particulate pollution characteristics and optical parameters in wastewater), 2000. ,
Turbidity-based monitoring of particle concentrations and flocculant requirement in wastewater pre-treatment, Water Sci. Technol, vol.50, issue.11, pp.173-178, 2004. ,