Heart Failure Devices: Implantable Cardioverter-Defibrillators and Biventricular Pacing Therapy, Circulation, vol.111, issue.24, 2005. ,
DOI : 10.1161/CIRCULATIONAHA.104.481267
Sudden Cardiac Death, Circulation, vol.98, issue.21, pp.2334-2351, 1998. ,
DOI : 10.1161/01.CIR.98.21.2334
Frequency of Sudden Cardiac Death and Profiles of Risk, The American Journal of Cardiology, vol.80, issue.5, pp.10-19, 1997. ,
DOI : 10.1016/S0002-9149(97)00477-3
The evolution of pacemakers, IEEE Engineering in Medicine and Biology Magazine, vol.25, issue.3, pp.38-48, 2006. ,
DOI : 10.1109/MEMB.2006.1636350
The cardiac pacemaker, function and malfunction: 1st Ed, 1983. ,
Design of Pacemakers, 1995. ,
Design of Pacemakers Fundamentals of Human Physiology, Cengage Learning, 1995. ,
The Evolution of Pacemakers, Sinnaeve " Cardiac Pacemakers step by step " Blackwell publishing 2004. [9] National Heart Lung Blood Institute, pp.2005-461, 2006. ,
Denis Flandre « Low power analog CMOS for cardiac pacemakers ,
The laws of electrical stimulation of cardiac tissue, Proceedings of the IEEE, vol.84, issue.3, 1996. ,
DOI : 10.1109/5.486739
Pacemaker Review Professor of Anesthesiology Electrode-Heart Interface: Definition of the Ideal Electrode, Pacing and Clinical Electrophysiology, vol.6, issue.14 2, pp.410-421, 1983. ,
Long-Term Assessment of Unipolar and Bipolar Stimulation and Sensing Thresholds Using a Lead Configuration Programmable Pacemaker, JACC, 1985. ,
The ventricular endocardial electrogram and pacemaker sensing, J. Cardiovascular and Thoracic Surg, vol.73, pp.258-266, 1977. ,
Cardiac pacing and pacemakers III, 1977. ,
DOI : 10.1016/s0002-8703(77)80078-1
Recent Advances in Pacemaker Lead Technology, Cardiac Electrophysiology Review, 1999. ,
Implanting a Left Ventricular Pacemaker Lead, Indian Heart J, vol.59, pp.197-204, 2007. ,
Phrenic Nerve Stimulation: An Unexpected Complication of ,
Medtronic, Inc. stimulation lead photo Publications 1. I. Seoudi Multi-electrode system for pacemaker applications, IEEE ICECS, vol.23, 2011. ,
Innovative Multi-electrode Communication Scheme for Cardiac Pacemakers, TBME, vol.2012 ,
Cardiac Pacing and ICDs, 2008. ,
Implanting a left ventricular pacemaker lead, Indian Heart J, vol.59, issue.2, pp.197-204, 2007. ,
Implantable satellite effectors " US patent, pp.7640060-7640062 ,
Selective activation of electrodes within an implantable lead " US patent, pp.6473653-6473654 ,
Circuit for controlled commutation of multiplexed electrodes for an active implantable medical device " US patent ,
Telecommunications and data communications handbook, 2007. ,
DOI : 10.1002/9780470127247
Low power analog CMOS for cardiac pacemakers: design and optimization in Bulk and SOI technologies, 2004. ,
DOI : 10.1007/978-1-4757-5683-8
Implanting a left ventricular pacemaker lead, Indian Heart J, 2007. ,
Computer aided design of microelectronic circuits and systems, 1987. ,
Implantable cardioverter defibrillator therapy, 1996. ,
Design challenges for prototypical and emerging memory concepts relying on resistance switching, pp.978-979 ,
SPICE modeling of magnetic tunnel junctions written by spin-transfer torque, J. Phys. D: Appl. Phys, pp.43-215001, 2010. ,
SPICE Macromodel of Spin-Torque-Transfer-Operated Magnetic Tunnel Junctions, IEEE Transactions on Electron Devices, vol.57, issue.6, 2010. ,
DOI : 10.1109/TED.2010.2047073
Dynamic compact model of Spin-Transfer Torque based Magnetic Tunnel Junction (MTJ), 2009 4th International Conference on Design & Technology of Integrated Systems in Nanoscal Era, 2009. ,
DOI : 10.1109/DTIS.2009.4938040
The missing memristor found ,
SPICE modeling of memristive, memcapacitative and meminductive systems, 2009 European Conference on Circuit Theory and Design ,
DOI : 10.1109/ECCTD.2009.5274934
Circuit Elements With Memory: Memristors, Memcapacitors, and Meminductors, Proceedings of the IEEE, vol.97, issue.10 ,
DOI : 10.1109/JPROC.2009.2021077
Digital Logic Implementation in Memrstor-based Crossbars ,
Nonvolatile memristor memory, Proceedings of the 2009 International Conference on Computer-Aided Design, ICCAD '09 ,
DOI : 10.1145/1687399.1687491
Memristor-based fine resolution programmable resistance and its applications, 2009 International Conference on Communications, Circuits and Systems ,
DOI : 10.1109/ICCCAS.2009.5250376
Carbon Nanotube Based Memory Development and Testing, 2007 IEEE Aerospace Conference ,
DOI : 10.1109/AERO.2007.353104
Carbon Nanotube-Based Nonvolatile Random Access Memory for Molecular Computing, Journal of Nuclear Medicine JNM figure, vol.18 ,
A Memristor SPICE Implementation and a New Approach for Magnetic Flux-Controlled Memristor Modeling, IEEE Transactions on Nanotechnology, vol.10, issue.2, 2011. ,
DOI : 10.1109/TNANO.2009.2038051
N-channel versus p-channel flash EEPROM-which one has better reliabilities, 2001 IEEE International Reliability Physics Symposium Proceedings. 39th Annual (Cat. No.00CH37167), 2001. ,
DOI : 10.1109/RELPHY.2001.922884
Mass Insight PowerPoint, 2005. ,
Flash memory cells-an overview, Proceedings of the IEEE, vol.85, issue.8, 1997. ,
DOI : 10.1109/5.622505
URL : http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.323.6913
Multi-electrode system for pacemaker applications, 2011 18th IEEE International Conference on Electronics, Circuits, and Systems, 2011. ,
DOI : 10.1109/ICECS.2011.6122230
Innovative Multi-electrode Communication Scheme for Cardiac Pacemakers, TBME, vol.2012 ,
DOI : 10.1109/newcas.2012.6328980
Default connection in multi-electrode leads for cardiac pacemakers, 10th IEEE International NEWCAS Conference, 2012. ,
DOI : 10.1109/NEWCAS.2012.6328980
Module de commutation contrôlée de sonde multiélectrode pour un dispositif médical implantable actif », filed one 13, 2011. ,