C. Ramanathan, R. N. Ghanem, P. Jia, K. Ryu, and Y. Rudy, Noninvasive electrocardiographic imaging for cardiac electrophysiology and arrhythmia, Nature Medicine, vol.10, issue.4, pp.422-428, 2004.
DOI : 10.1038/nm1011

J. Laissy, R. Bazeli, and J. Serfaty, Tomodensitom??trie cardiaque??: indications et perspectives, Presse Médicale, pp.724-731, 2008.
DOI : 10.1016/j.lpm.2007.07.039

C. Kasai, K. Namekawa, A. Koyano, and R. Omoto, Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique, IEEE Transactions on Sonics and Ultrasonics, vol.32, issue.3, pp.458-464, 1985.
DOI : 10.1109/T-SU.1985.31615

S. Severino, P. Caso, M. Galderisi, L. De-simone, A. Petrocelli et al., Use of pulsed Doppler tissue imaging to assess regional left ventricular diastolic dysfunction in hypertrophic cardiomyopathy, The American Journal of Cardiology, vol.82, issue.11, pp.1394-1398, 1998.
DOI : 10.1016/S0002-9149(98)00648-1

M. J. Garcia, L. Rodriguez, M. Ares, B. P. Griffin, J. D. Thomas et al., Differentiation of constrictive pericarditis from restrictive cardiomyopathy: Assessment of left ventricular diastolic velocities in longitudinal axis by doppler tissue imaging, Journal of the American College of Cardiology, vol.27, issue.1, pp.108-114, 1996.
DOI : 10.1016/0735-1097(95)00434-3

J. D. 'hooge, A. Heimdal, F. Jamal, T. Kukulski, B. Bijnens et al., Regional Strain and Strain Rate Measurements by Cardiac Ultrasound: Principles, Implementation and Limitations, European Journal of Echocardiography, vol.1, issue.3, pp.154-170, 2000.
DOI : 10.1053/euje.2000.0031

S. Langeland, J. D-'hooge, P. F. Wouters, H. A. Leather, P. Claus et al., Experimental Validation of a New Ultrasound Method for the Simultaneous Assessment of Radial and Longitudinal Myocardial Deformation Independent of Insonation Angle, Circulation, vol.112, issue.14, pp.2157-2162, 2005.
DOI : 10.1161/CIRCULATIONAHA.105.554006

H. Kanai, Propagation of spontaneously actuated pulsive vibration in human heart wall and in vivo viscoelasticity estimation, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.52, issue.11, pp.1931-1942, 2005.
DOI : 10.1109/TUFFC.2005.1561662

G. Montaldo, M. Tanter, J. Bercoff, N. Benech, and M. Fink, Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, issue.3, pp.489-506, 2009.
DOI : 10.1109/TUFFC.2009.1067

J. Bercoff, M. Tanter, and M. Fink, Supersonic shear imaging: a new technique for soft tissue elasticity mapping, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.51, issue.4, pp.396-409, 2004.
DOI : 10.1109/TUFFC.2004.1295425

J. Bercoff, L'imagerie échographique ultrarapide et son application à l'étude de la viscoelasticité du corps humain, ESPCI ParisTECH, 2004.

M. Muller, J. Gennisson, T. Deffieux, M. Tanter, and M. Fink, Quantitative Viscoelasticity Mapping of Human Liver Using Supersonic Shear Imaging: Preliminary In Vivo Feasability Study, Ultrasound in Medicine & Biology, vol.35, issue.2, pp.219-229, 2009.
DOI : 10.1016/j.ultrasmedbio.2008.08.018

T. Nguyen, J. Aubry, D. Touboul, M. Fink, J. Gennisson et al., Monitoring of Cornea Elastic Properties Changes during UV-A/Riboflavin-Induced Corneal Collagen Cross-Linking using Supersonic Shear Wave Imaging: A Pilot Study, Investigative Opthalmology & Visual Science, vol.53, issue.9, pp.5948-5954, 2012.
DOI : 10.1167/iovs.11-9142

J. Brum, M. Bernal, J. L. Gennisson, and M. Tanter, evaluation of the elastic anisotropy of the human Achilles tendon using shear wave dispersion analysis, Physics in Medicine and Biology, vol.59, issue.3, pp.505-523, 2014.
DOI : 10.1088/0031-9155/59/3/505

M. Pernot, M. Couade, P. Mateo, B. Crozatier, R. Fischmeister et al., Real-Time Assessment of Myocardial Contractility Using Shear Wave Imaging, Journal of the American College of Cardiology, vol.58, issue.1, pp.65-72, 2011.
DOI : 10.1016/j.jacc.2011.02.042

M. Couade, M. Pernot, E. Messas, A. Bel, M. Ba et al., In Vivo Quantitative Mapping of Myocardial Stiffening and Transmural Anisotropy During the Cardiac Cycle, IEEE Transactions on Medical Imaging, vol.30, issue.2, pp.295-305, 2011.
DOI : 10.1109/TMI.2010.2076829

E. Macé, G. Montaldo, I. Cohen, M. Baulac, M. Fink et al., Functional ultrasound imaging of the brain, Nature Methods, vol.12, issue.8, pp.662-664, 2011.
DOI : 10.1038/nmeth.1530

C. Demené, M. Pernot, V. Biran, M. Alison, M. Fink et al., Ultrafast Doppler Reveals the Mapping of Cerebral Vascular Resistivity in Neonates, Journal of Cerebral Blood Flow & Metabolism, vol.82, issue.6, pp.1009-1017, 2014.
DOI : 10.1364/OE.15.004083

D. A. Shcherbakova, C. Papadacci, A. Swillens, A. Caenen, S. De-bock et al., Testing of the Horse Aorta, Advances in Mechanical Engineering, vol.4, issue.2, p.272586, 2014.
DOI : 10.1016/j.ultrasmedbio.2013.09.014

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, Shear Wave Imaging of the heart using a cardiac phased array with coherent spatial compound, 2012 IEEE International Ultrasonics Symposium, pp.2023-2026, 2012.
DOI : 10.1109/ULTSYM.2012.0506

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, High-contrast ultrafast imaging of the heart, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.2, pp.288-301, 2014.
DOI : 10.1109/TUFFC.2014.6722614

URL : https://hal.archives-ouvertes.fr/hal-01057544

C. Papadacci, M. Tanter, M. Pernot, and M. Fink, Ultrasound backscatter tensor imaging (BTI): analysis of the spatial coherence of ultrasonic speckle in anisotropic soft tissues, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.6, pp.986-996, 2014.
DOI : 10.1109/TUFFC.2014.2994

URL : https://hal.archives-ouvertes.fr/hal-01096016

R. T. Lee and R. D. Kamm, Vascular mechanics for the cardiologist, Journal of the American College of Cardiology, vol.23, issue.6, pp.1289-1295, 1994.
DOI : 10.1016/0735-1097(94)90369-7

M. F. O-'rourke, J. A. Staessen, C. Vlachopoulos, D. Duprez, G. Érard et al., Clinical applications of arterial stiffness; definitions and reference values, American Journal of Hypertension, vol.15, issue.5, pp.426-444, 2002.
DOI : 10.1016/S0895-7061(01)02319-6

J. L. Cavalcante, J. A. Lima, A. Redheuil, and M. H. , Aortic Stiffness, Journal of the American College of Cardiology, vol.57, issue.14, pp.1511-1522, 2011.
DOI : 10.1016/j.jacc.2010.12.017

K. Cheng, C. R. Baker, G. Hamilton, A. P. Hoeks, and A. M. Seifalian, Arterial Elastic Properties and Cardiovascular Risk/Event, European Journal of Vascular and Endovascular Surgery, vol.24, issue.5, pp.383-397, 2002.
DOI : 10.1053/ejvs.2002.1756

S. Laurent, P. Boutouyrie, R. Asmar, I. Gautier, B. Laloux et al., Aortic Stiffness Is an Independent Predictor of All-Cause and Cardiovascular Mortality in Hypertensive Patients, Hypertension, vol.37, issue.5, pp.1236-1241, 2001.
DOI : 10.1161/01.HYP.37.5.1236

R. Asmar, A. Benetos, J. Topouchian, P. Laurent, B. Pannier et al., Assessment of Arterial Distensibility by Automatic Pulse Wave Velocity Measurement : Validation and Clinical Application Studies, Hypertension, vol.26, issue.3, pp.485-490, 1995.
DOI : 10.1161/01.HYP.26.3.485

M. R. Nelson, J. Stepanek, M. Cevette, M. Covalciuc, R. T. Hurst et al., Noninvasive Measurement of Central Vascular Pressures With Arterial Tonometry: Clinical Revival of the Pulse Pressure Waveform?, Mayo Clinic Proceedings, vol.85, issue.5, pp.460-472, 2010.
DOI : 10.4065/mcp.2009.0336

P. Segers, S. Carlier, A. Pasquet, S. I. Rabben, L. R. Hellevik et al., Individualizing the aorto-radial pressure transfer function: feasibility of a model-based approach, Am. J. Physiol. -Heart Circ. Physiol, vol.279, issue.2, pp.542-549, 2000.

S. A. Hope, D. B. Tay, I. T. Meredith, and J. D. Cameron, Use of arterial transfer functions for the derivation of aortic waveform characteristics, Journal of Hypertension, vol.21, issue.7, pp.1299-1305, 2003.
DOI : 10.1097/00004872-200307000-00017

H. Kanai, Propagation of spontaneously actuated pulsive vibration in human heart wall and in vivo viscoelasticity estimation, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.52, issue.11, pp.1931-1942, 2005.
DOI : 10.1109/TUFFC.2005.1561662

A. Eriksson, E. Greiff, T. Loupas, M. Persson, and P. Pesque, Arterial pulse wave velocity with tissue doppler imaging, Ultrasound in Medicine & Biology, vol.28, issue.5, pp.571-580, 2002.
DOI : 10.1016/S0301-5629(02)00495-7

G. L. Sorensen, J. B. Jensen, J. Udesen, I. K. Holfort, and J. A. Jensen, Pulse wave velocity in the carotid artery, 2008 IEEE Ultrasonics Symposium, pp.1386-1389, 2008.
DOI : 10.1109/ULTSYM.2008.0336

E. Konofagou, W. Lee, J. Luo, J. Provost, and J. Vappou, Physiologic Cardiovascular Strain and Intrinsic Wave Imaging, Annual Review of Biomedical Engineering, vol.13, issue.1, pp.477-505, 2011.
DOI : 10.1146/annurev-bioeng-071910-124721

M. Couade, M. Pernot, E. Messas, J. Emmerich, A. Hagège et al., Ultrafast imaging of the arterial pulse wave, IRBM, vol.32, issue.2, pp.106-108, 2011.
DOI : 10.1016/j.irbm.2011.01.012

J. Luo, R. X. Li, and E. E. Konofagou, Pulse Wave Imaging (PWI) of the human carotid artery: An in vivo feasibility study, The Journal of the Acoustical Society of America, vol.131, issue.4, pp.174-181, 2012.
DOI : 10.1121/1.4708297

J. Bercoff, M. Tanter, and M. Fink, Supersonic shear imaging: a new technique for soft tissue elasticity mapping, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.51, issue.4, pp.396-409, 2004.
DOI : 10.1109/TUFFC.2004.1295425

M. Muller, J. Gennisson, T. Deffieux, M. Tanter, and M. Fink, Quantitative Viscoelasticity Mapping of Human Liver Using Supersonic Shear Imaging: Preliminary In Vivo Feasability Study, Ultrasound in Medicine & Biology, vol.35, issue.2, pp.219-229, 2009.
DOI : 10.1016/j.ultrasmedbio.2008.08.018

T. Nguyen, J. Aubry, D. Touboul, M. Fink, J. Gennisson et al., Monitoring of Cornea Elastic Properties Changes during UV-A/Riboflavin-Induced Corneal Collagen Cross-Linking using Supersonic Shear Wave Imaging: A Pilot Study, Investigative Opthalmology & Visual Science, vol.53, issue.9, pp.5948-5954, 2012.
DOI : 10.1167/iovs.11-9142

J. Brum, M. Bernal, J. L. Gennisson, and M. Tanter, evaluation of the elastic anisotropy of the human Achilles tendon using shear wave dispersion analysis, Physics in Medicine and Biology, vol.59, issue.3, pp.505-523, 2014.
DOI : 10.1088/0031-9155/59/3/505

M. Couade, M. Pernot, E. Messas, A. Bel, M. Ba et al., In Vivo Quantitative Mapping of Myocardial Stiffening and Transmural Anisotropy During the Cardiac Cycle, IEEE Transactions on Medical Imaging, vol.30, issue.2, pp.295-305, 2011.
DOI : 10.1109/TMI.2010.2076829

M. Pernot, M. Couade, P. Mateo, B. Crozatier, R. Fischmeister et al., Real-Time Assessment of Myocardial Contractility Using Shear Wave Imaging, Journal of the American College of Cardiology, vol.58, issue.1, pp.65-72, 2011.
DOI : 10.1016/j.jacc.2011.02.042

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, Shear Wave Imaging of the heart using a cardiac phased array with coherent spatial compound, 2012 IEEE International Ultrasonics Symposium, pp.2023-2026, 2012.
DOI : 10.1109/ULTSYM.2012.0506

M. Couade, M. Pernot, C. Prada, E. Messas, J. Emmerich et al., Quantitative Assessment of Arterial Wall Biomechanical Properties Using Shear Wave Imaging, Ultrasound in Medicine & Biology, vol.36, issue.10, pp.1662-1676, 2010.
DOI : 10.1016/j.ultrasmedbio.2010.07.004

P. R. Hoskins, Physical Properties of Tissues Relevant to Arterial Ultrasound Imaging and Blood Velocity Measurement, Ultrasound in Medicine & Biology, vol.33, issue.10, pp.1527-1539, 2007.
DOI : 10.1016/j.ultrasmedbio.2007.04.020

Y. C. Fung, Biomechanics: Mechanical Properties of Living Tissues, 1993.

G. Montaldo, M. Tanter, J. Bercoff, N. Benech, and M. Fink, Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, issue.3, pp.489-506, 2009.
DOI : 10.1109/TUFFC.2009.1067

A. V. Kamenskiy, Y. A. Dzenis, J. N. Mactaggart, T. G. Lynch, J. Kazmi et al., Nonlinear Mechanical Behavior of The Human Common, External, and Internal Carotid Arteries In??Vivo, Journal of Surgical Research, vol.176, issue.1, pp.329-336, 2012.
DOI : 10.1016/j.jss.2011.09.058

R. H. Cox, Arterial wall mechanics and composition and the effects of smooth muscle activation, Am. J. Physiol. --Leg. Content, vol.229, issue.3, pp.807-812, 1975.

R. H. Cox, Basis for the altered arterial wall mechanics in the spontaneously hypertensive rat, Hypertension, vol.3, issue.4, pp.485-495, 1981.
DOI : 10.1161/01.HYP.3.4.485

C. Bussy, P. Boutouyrie, P. Lacolley, P. Challande, and S. Laurent, Intrinsic Stiffness of the Carotid Arterial Wall Material in Essential Hypertensives, Hypertension, vol.35, issue.5, pp.1049-1054, 2000.
DOI : 10.1161/01.HYP.35.5.1049

J. D. 'hooge, A. Heimdal, F. Jamal, T. Kukulski, B. Bijnens et al., Regional Strain and Strain Rate Measurements by Cardiac Ultrasound: Principles, Implementation and Limitations, European Journal of Echocardiography, vol.1, issue.3, pp.154-170, 2000.
DOI : 10.1053/euje.2000.0031

G. R. Sutherland, B. Bijnens, and W. N. Mcdicken, Tissue Doppler Echocardiography., Echocardiography, vol.90, issue.5, pp.445-453, 1999.
DOI : 10.1002/mrm.1910270107

M. Pernot, K. Fujikura, S. D. Fung-kee-fung, and E. E. Konofagou, ECG-gated, Mechanical and Electromechanical Wave Imaging of Cardiovascular Tissues In Vivo, Ultrasound in Medicine & Biology, vol.33, issue.7, pp.1075-1085, 2007.
DOI : 10.1016/j.ultrasmedbio.2007.02.003

J. Provost, W. Lee, K. Fujikura, and E. E. Konofagou, Electromechanical Wave Imaging of Normal and Ischemic Hearts <emphasis emphasistype="italic">In Vivo</emphasis>, IEEE Transactions on Medical Imaging, vol.29, issue.3, pp.625-635, 2010.
DOI : 10.1109/TMI.2009.2030186

G. Montaldo, M. Tanter, J. Bercoff, N. Benech, and M. Fink, Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, issue.3, pp.489-506, 2009.
DOI : 10.1109/TUFFC.2009.1067

J. Bercoff, M. Tanter, and M. Fink, Supersonic shear imaging: a new technique for soft tissue elasticity mapping, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.51, issue.4, pp.396-409, 2004.
DOI : 10.1109/TUFFC.2004.1295425

M. Couade, M. Pernot, E. Messas, A. Bel, M. Ba et al., In Vivo Quantitative Mapping of Myocardial Stiffening and Transmural Anisotropy During the Cardiac Cycle, IEEE Transactions on Medical Imaging, vol.30, issue.2, pp.295-305, 2011.
DOI : 10.1109/TMI.2010.2076829

R. R. Bouchard, S. J. Hsu, M. L. Palmeri, N. C. Rouze, K. R. Nightingale et al., Acoustic Radiation Force-Driven Assessment of Myocardial Elasticity Using the Displacement Ratio Rate (DRR) Method, Ultrasound in Medicine & Biology, vol.37, issue.7, pp.1087-1100, 2011.
DOI : 10.1016/j.ultrasmedbio.2011.04.005

M. Pernot, M. Couade, P. Mateo, B. Crozatier, R. Fischmeister et al., Real-Time Assessment of Myocardial Contractility Using Shear Wave Imaging, Journal of the American College of Cardiology, vol.58, issue.1, pp.65-72, 2011.
DOI : 10.1016/j.jacc.2011.02.042

W. Lee, M. Couade, C. Flanagan, M. Fink, M. Pernot et al., Noninvasive assessment of myocardial anisotropy in vitro and in vivo using Supersonic Shear Wave Imaging, 2010 IEEE International Ultrasonics Symposium, pp.690-693, 2010.
DOI : 10.1109/ULTSYM.2010.5935898

W. Lee, M. Pernot, M. Couade, E. Messas, P. Bruneval et al., Mapping myocardial fiber orientation using echocardiography-based shear wave imaging, IEEE Trans. Med. Imaging, vol.31, issue.3, pp.554-562, 2012.

B. Osmanski, M. Pernot, G. Montaldo, A. Bel, E. Messas et al., Ultrafast Doppler Imaging of Blood Flow Dynamics in the Myocardium, IEEE Transactions on Medical Imaging, vol.31, issue.8, pp.1661-1668, 2012.
DOI : 10.1109/TMI.2012.2203316

H. Kanai, Propagation of spontaneously actuated pulsive vibration in human heart wall and in vivo viscoelasticity estimation, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.52, issue.11, pp.1931-1942, 2005.
DOI : 10.1109/TUFFC.2005.1561662

J. Provost, V. T. Nguyen, D. Legrand, S. Okrasinski, A. Costet et al., Electromechanical wave imaging for arrhythmias, Physics in Medicine and Biology, vol.56, issue.22, pp.1-11, 2011.
DOI : 10.1088/0031-9155/56/22/F01

J. Provost, S. Thiébaut, J. Luo, and E. E. Konofagou, Single-heartbeat electromechanical wave imaging with optimal strain estimation using temporally unequispaced acquisition sequences, Physics in Medicine and Biology, vol.57, issue.4, pp.1095-1112, 2012.
DOI : 10.1088/0031-9155/57/4/1095

J. Provost, A. Gambhir, J. Vest, H. Garan, and E. E. Konofagou, A clinical feasibility study of atrial and ventricular electromechanical wave imaging, Heart Rhythm, vol.10, issue.6, pp.856-862, 2013.
DOI : 10.1016/j.hrthm.2013.02.028

J. Lu and J. F. Greenleaf, Pulse-echo imaging using a nondiffracting beam transducer, Ultrasound in Medicine & Biology, vol.17, issue.3, pp.265-281, 1991.
DOI : 10.1016/0301-5629(91)90048-2

L. Sandrin, S. Catheline, M. Tanter, X. Hennequin, and M. Fink, Time-Resolved Pulsed Elastography with Ultrafast Ultrasonic Imaging, Ultrasonic Imaging, vol.21, issue.4, pp.259-272, 1999.
DOI : 10.1177/016173469902100402

J. Lu, J. Cheng, and J. Wang, High frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings high frame rate imaging system for limited diffraction array beam imaging with square-wave aperture weightings, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.53, issue.10, pp.1796-1812, 2006.
DOI : 10.1109/TUFFC.2006.112

L. Tong, H. Gao, H. F. Choi, and J. D-'hooge, Video 1, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.59, issue.8, pp.1654-1663, 2012.
DOI : 10.1109/TUFFC.2012.2371/mm1

I. K. Ekroll, A. Swillens, P. Segers, T. Dahl, H. Torp et al., Figure 14, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.60, issue.4, pp.727-738, 2013.
DOI : 10.1109/TUFFC.2013.2621/mm2

G. Montaldo, M. Tanter, J. Bercoff, N. Benech, and M. Fink, Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, issue.3, pp.489-506, 2009.
DOI : 10.1109/TUFFC.2009.1067

G. R. Lockwood, J. R. Talman, and S. S. Brunke, Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.45, issue.4, pp.980-988, 1998.
DOI : 10.1109/58.710573

G. R. Hazard, Theoretical assessment of a synthetic aperture beamformer for real-time 3-D imaging, Ultrason. Ferroelectr. Freq. Control IEEE Trans. On, issue.4, pp.972-980, 1999.

S. I. Nikolov, J. Kortbek, and J. A. Jensen, Practical applications of synthetic aperture imaging, 2010 IEEE International Ultrasonics Symposium, 2010.
DOI : 10.1109/ULTSYM.2010.5935627

S. I. Nikolov, Synthetic aperture tissue and flow ultrasound imaging, 2001.

J. A. Jensen, S. I. Nikolov, K. L. Gammelmark, and M. H. Pedersen, Synthetic aperture ultrasound imaging, Ultrasonics, vol.44, pp.5-15, 2006.
DOI : 10.1016/j.ultras.2006.07.017

J. A. Jensen, Field: A Program for Simulating Ultrasound Systems, Baltic Conference on Biomedical Imaging Published in Medical & Biological Engineering & Computing, vol.34, pp.351-353, 1996.

J. A. Jensen and N. B. Svendsen, Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.39, issue.2, pp.262-267, 1992.
DOI : 10.1109/58.139123

B. Osmanski, D. Maresca, E. Messas, M. Tanter, and M. Pernot, Transthoracic ultrafast Doppler imaging of human left ventricular hemodynamic function, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.8, pp.1268-1275, 2014.
DOI : 10.1109/TUFFC.2014.3033

J. Luo and E. E. Konofagou, Imaging of Wall Motion Coupled With Blood Flow Velocity in the Heart and Vessels in Vivo: A Feasibility Study, Ultrasound in Medicine & Biology, vol.37, issue.6, pp.980-995, 2011.
DOI : 10.1016/j.ultrasmedbio.2011.03.004

D. D. Streeter and D. L. Bassett, An engineering analysis of myocardial fiber orientation in pig's left ventricle in systole, The Anatomical Record, vol.101, issue.4, pp.503-511, 1966.
DOI : 10.1002/ar.1091550403

T. Arts, K. D. Costa, J. W. Covell, and A. D. Mcculloch, Relating myocardial laminar architecture to shear strain and muscle fiber orientation, Am. J. Physiol.-Heart Circ. Physiol, vol.280, issue.5, pp.2222-2229, 2001.

K. D. Costa, Y. Takayama, A. D. Mcculloch, and J. W. , Laminar fiber architecture and three-dimensional systolic mechanics in canine ventricular myocardium, Am. J. Physiol.-Heart Circ. Physiol, vol.276, issue.2, pp.595-607, 1999.

L. K. Waldman, D. Nosan, F. Villarreal, and J. W. , Relation between transmural deformation and local myofiber direction in canine left ventricle, Circulation Research, vol.63, issue.3, pp.550-562, 1988.
DOI : 10.1161/01.RES.63.3.550

D. A. Hooks, M. L. Trew, B. J. Caldwell, G. B. Sands, I. J. Legrice et al., Laminar Arrangement of Ventricular Myocytes Influences Electrical Behavior of the Heart, Circulation Research, vol.101, issue.10, pp.103-112, 2007.
DOI : 10.1161/CIRCRESAHA.107.161075

A. Kadish, M. Shinnar, E. N. Moore, J. H. Levine, C. W. Balke et al., Interaction of fiber orientation and direction of impulse propagation with anatomic barriers in anisotropic canine myocardium, Circulation, vol.78, issue.6, pp.1478-1494, 1988.
DOI : 10.1161/01.CIR.78.6.1478

D. E. Roberts, L. T. Hersh, and A. M. Scher, Influence of cardiac fiber orientation on wavefront voltage, conduction velocity, and tissue resistivity in the dog, Circulation Research, vol.44, issue.5, pp.701-712, 1979.
DOI : 10.1161/01.RES.44.5.701

B. Taccardi, E. Macchi, R. L. Lux, P. R. Ershler, S. Spaggiari et al., Effect of myocardial fiber direction on epicardial potentials, Circulation, vol.90, issue.6, pp.3076-3090, 1994.
DOI : 10.1161/01.CIR.90.6.3076

C. P. Fleming, C. M. Ripplinger, B. Webb, I. R. Efimov, and A. M. Rollins, Quantification of cardiac fiber orientation using optical coherence tomography, Journal of Biomedical Optics, vol.13, issue.3, p.30505, 2008.
DOI : 10.1117/1.2937470

H. Huang, C. Macgillivray, H. Kwon, J. Lammerding, J. Robbins et al., Three-dimensional cardiac architecture determined by two-photon microtomy, Journal of Biomedical Optics, vol.14, issue.4, p.44029, 2009.
DOI : 10.1117/1.3200939.7

E. W. Hsu, A. L. Muzikant, S. A. Matulevicius, R. C. Penland, and C. S. Henriquez, Magnetic resonance myocardial fiber-orientation mapping with direct histological correlation, Am. J. Physiol.-Heart Circ. Physiol, vol.274, issue.5, pp.1627-1634, 1998.

D. F. Scollan, A. Holmes, R. Winslow, and J. Forder, Histological validation of myocardial microstructure obtained from diffusion tensor magnetic resonance imaging, Am. J. Physiol.-Heart Circ. Physiol, vol.275, issue.6, pp.2308-2318, 1998.

T. G. Reese, R. M. Weisskoff, R. N. Smith, B. R. Rosen, R. E. Dinsmore et al., Imaging myocardial fiber architecturein vivo with magnetic resonance, Magnetic Resonance in Medicine, vol.19, issue.6, pp.786-791, 1995.
DOI : 10.1002/mrm.1910340603

W. I. Tseng, J. Dou, T. G. Reese, and V. J. Wedeen, Imaging myocardial fiber disarray and intramural strain hypokinesis in hypertrophic cardiomyopathy with MRI, Journal of Magnetic Resonance Imaging, vol.77, issue.1, pp.1-8, 2006.
DOI : 10.1002/jmri.20473

M. Wu, W. I. Tseng, M. M. Su, C. Liu, K. Chiou et al., Diffusion Tensor Magnetic Resonance Imaging Mapping the Fiber Architecture Remodeling in Human Myocardium After Infarction: Correlation With Viability and Wall Motion, Circulation, vol.114, issue.10, pp.1036-1045, 2006.
DOI : 10.1161/CIRCULATIONAHA.105.545863

H. Rimington, Echocardiography: A Practical Guide for Reporting, 2007.
DOI : 10.3109/9781435628120

S. L. Baldwin, K. R. Marutyan, M. Yang, K. D. Wallace, M. R. Holland et al., Measurements of the anisotropy of ultrasonic attenuation in freshly excised myocardium, The Journal of the Acoustical Society of America, vol.119, issue.5, p.3130, 2006.
DOI : 10.1121/1.2188333

S. A. Wickline, E. D. Verdonk, and J. G. Miller, Three-dimensional characterization of human ventricular myofiber architecture by ultrasonic backscatter., Journal of Clinical Investigation, vol.88, issue.2, p.438, 1991.
DOI : 10.1172/JCI115323

R. Sinkus, M. Tanter, S. Catheline, J. Lorenzen, C. Kuhl et al., Imaging anisotropic and viscous properties of breast tissue by magnetic resonance-elastography, Magnetic Resonance in Medicine, vol.8, issue.2, pp.372-387, 2005.
DOI : 10.1002/mrm.20355

J. Gennisson, T. Deffieux, E. Macé, G. Montaldo, M. Fink et al., Viscoelastic and Anisotropic Mechanical Properties of in vivo Muscle Tissue Assessed by Supersonic Shear Imaging, Ultrasound in Medicine & Biology, vol.36, issue.5, pp.789-801, 2010.
DOI : 10.1016/j.ultrasmedbio.2010.02.013

J. Bercoff, M. Tanter, and M. Fink, Supersonic shear imaging: a new technique for soft tissue elasticity mapping, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.51, issue.4, pp.396-409, 2004.
DOI : 10.1109/TUFFC.2004.1295425

W. Lee, M. Pernot, M. Couade, E. Messas, P. Bruneval et al., Mapping myocardial fiber orientation using echocardiography-based shear wave imaging, IEEE Trans. Med. Imaging, vol.31, issue.3, pp.554-562, 2012.

W. Lee, M. Couade, C. Flanagan, M. Fink, M. Pernot et al., Noninvasive assessment of myocardial anisotropy in vitro and in vivo using Supersonic Shear Wave Imaging, 2010 IEEE International Ultrasonics Symposium, pp.690-693, 2010.
DOI : 10.1109/ULTSYM.2010.5935898

W. Lee, B. Larrat, M. Pernot, and M. Tanter, Ultrasound elastic tensor imaging: comparison with MR diffusion tensor imaging in the myocardium, Physics in Medicine and Biology, vol.57, issue.16, pp.5075-5095, 2012.
DOI : 10.1088/0031-9155/57/16/5075

M. Couade, M. Pernot, E. Messas, A. Bel, M. Ba et al., In Vivo Quantitative Mapping of Myocardial Stiffening and Transmural Anisotropy During the Cardiac Cycle, IEEE Transactions on Medical Imaging, vol.30, issue.2, pp.295-305, 2011.
DOI : 10.1109/TMI.2010.2076829

M. Pernot, M. Couade, P. Mateo, B. Crozatier, R. Fischmeister et al., Real-Time Assessment of Myocardial Contractility Using Shear Wave Imaging, Journal of the American College of Cardiology, vol.58, issue.1, pp.65-72, 2011.
DOI : 10.1016/j.jacc.2011.02.042

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, Shear Wave Imaging of the heart using a cardiac phased array with coherent spatial compound, 2012 IEEE International Ultrasonics Symposium, pp.2023-2026, 2012.
DOI : 10.1109/ULTSYM.2012.0506

P. Song, H. Zhao, M. W. Urban, A. Manduca, S. V. Pislaru et al., Robust shear wave motion tracking using ultrasound harmonic imaging, The Journal of the Acoustical Society of America, vol.134, issue.5, p.4010, 2013.
DOI : 10.1121/1.4830628

R. Mallart and M. Fink, The van Cittert???Zernike theorem in pulse echo measurements, The Journal of the Acoustical Society of America, vol.90, issue.5, pp.2718-2727, 1991.
DOI : 10.1121/1.401867

W. F. Walker and G. E. Trahey, Speckle coherence and implications for adaptive imaging, The Journal of the Acoustical Society of America, vol.101, issue.4, pp.1847-1858, 1997.
DOI : 10.1121/1.418235

R. Mallart and M. Fink, Adaptive focusing in scattering media through sound???speed inhomogeneities: The van Cittert Zernike approach and focusing criterion, The Journal of the Acoustical Society of America, vol.96, issue.6, pp.3721-3732, 1994.
DOI : 10.1121/1.410562

K. W. Hollman, K. W. Rigby, and M. O. , Coherence factor of speckle from a multi-row probe, 1999 IEEE Ultrasonics Symposium. Proceedings. International Symposium (Cat. No.99CH37027), pp.1257-1260, 1999.
DOI : 10.1109/ULTSYM.1999.849225

P. Li and M. Li, Adaptive imaging using the generalized coherence factor, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, vol.50, issue.2, pp.128-141, 2003.

M. A. Lediju, G. E. Trahey, B. C. Byram, and J. J. Dahl, Short-lag spatial coherence of backscattered echoes: imaging characteristics, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.58, issue.7, pp.1377-1388, 2011.
DOI : 10.1109/TUFFC.2011.1957

J. J. Dahl, M. Jakovljevic, G. F. Pinton, and G. E. Trahey, Harmonic spatial coherence imaging: an ultrasonic imaging method based on backscatter coherence, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.59, issue.4, pp.648-659, 2012.
DOI : 10.1109/TUFFC.2012.2243

A. Derode and M. Fink, Spatial coherence of ultrasonic speckle in composites, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.40, issue.6, pp.666-675, 1993.
DOI : 10.1109/58.248209

G. Montaldo, M. Tanter, J. Bercoff, N. Benech, and M. Fink, Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, issue.3, pp.489-506, 2009.
DOI : 10.1109/TUFFC.2009.1067

M. Tanter, J. Bercoff, L. Sandrin, and M. Fink, Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.49, issue.10, pp.1363-1374, 2002.
DOI : 10.1109/TUFFC.2002.1041078

M. Karaman, P. Li, and M. O. , Synthetic aperture imaging for small scale systems, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.42, issue.3, pp.429-442, 1995.
DOI : 10.1109/58.384453

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, High-contrast ultrafast imaging of the heart, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.2, pp.288-301, 2014.
DOI : 10.1109/TUFFC.2014.6722614

URL : https://hal.archives-ouvertes.fr/hal-01057544

M. Muller, J. Gennisson, T. Deffieux, R. Sinkus, P. Annic et al., 8C-5 Full 3D Inversion of the Viscoelasticity Wave Propagation Problem for 3D Ultrasound Elastography in Breast Cancer Diagnosis, 2007 IEEE Ultrasonics Symposium Proceedings, pp.672-675, 2007.
DOI : 10.1109/ULTSYM.2007.174

J. Provost, A. Gambhir, J. Vest, H. Garan, and E. E. Konofagou, A clinical feasibility study of atrial and ventricular electromechanical wave imaging, Heart Rhythm, vol.10, issue.6, pp.856-862, 2013.
DOI : 10.1016/j.hrthm.2013.02.028

W. Lee, M. Pernot, M. Couade, E. Messas, P. Bruneval et al., Mapping myocardial fiber orientation using echocardiography-based shear wave imaging, IEEE Trans. Med. Imaging, vol.31, issue.3, pp.554-562, 2012.

G. Montaldo, M. Tanter, J. Bercoff, N. Benech, and M. Fink, Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.56, issue.3, pp.489-506, 2009.
DOI : 10.1109/TUFFC.2009.1067

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, High-contrast ultrafast imaging of the heart, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.2, pp.288-301, 2014.
DOI : 10.1109/TUFFC.2014.6722614

URL : https://hal.archives-ouvertes.fr/hal-01057544

G. R. Lockwood, J. R. Talman, and S. S. Brunke, Real-time 3-D ultrasound imaging using sparse synthetic aperture beamforming, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.45, issue.4, pp.980-988, 1998.
DOI : 10.1109/58.710573

S. Nikolov and J. A. Jensen, Virtual ultrasound sources in high-resolution ultrasound imaging, pp.395-405, 2002.

S. I. Nikolov, J. Kortbek, and J. A. Jensen, Practical applications of synthetic aperture imaging, 2010 IEEE International Ultrasonics Symposium, 2010.
DOI : 10.1109/ULTSYM.2010.5935627

J. Bercoff, M. Tanter, and M. Fink, Supersonic shear imaging: a new technique for soft tissue elasticity mapping, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.51, issue.4, pp.396-409, 2004.
DOI : 10.1109/TUFFC.2004.1295425

C. Demené, M. Pernot, V. Biran, M. Alison, M. Fink et al., Ultrafast Doppler Reveals the Mapping of Cerebral Vascular Resistivity in Neonates, Journal of Cerebral Blood Flow & Metabolism, vol.82, issue.6, pp.1009-1017, 2014.
DOI : 10.1364/OE.15.004083

E. Macé, G. Montaldo, I. Cohen, M. Baulac, M. Fink et al., Functional ultrasound imaging of the brain, Nature Methods, vol.12, issue.8, pp.662-664, 2011.
DOI : 10.1038/nmeth.1530

B. Osmanski, D. Maresca, E. Messas, M. Tanter, and M. Pernot, Transthoracic ultrafast Doppler imaging of human left ventricular hemodynamic function, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.8, pp.1268-1275, 2014.
DOI : 10.1109/TUFFC.2014.3033

M. Couade, M. Pernot, E. Messas, J. Emmerich, A. Hagège et al., Ultrafast imaging of the arterial pulse wave, IRBM, vol.32, issue.2, pp.106-108, 2011.
DOI : 10.1016/j.irbm.2011.01.012

J. Luo, R. X. Li, and E. E. Konofagou, Pulse Wave Imaging (PWI) of the human carotid artery: An in vivo feasibility study, The Journal of the Acoustical Society of America, vol.131, issue.4, pp.174-181, 2012.
DOI : 10.1121/1.4708297

B. Osmanski, D. Maresca, E. Messas, M. Tanter, and M. Pernot, Transthoracic ultrafast Doppler imaging of human left ventricular hemodynamic function, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.8, pp.1268-1275, 2014.
DOI : 10.1109/TUFFC.2014.3033

B. Denarie, T. Bjastad, and H. Torp, Multi-line transmission in 3-D with reduced crosstalk artifacts: a proof of concept study, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.60, issue.8, pp.1708-1718, 2013.
DOI : 10.1109/TUFFC.2013.2752

C. Papadacci, M. Tanter, M. Pernot, and M. Fink, Ultrasound backscatter tensor imaging (BTI): analysis of the spatial coherence of ultrasonic speckle in anisotropic soft tissues, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.6, pp.986-996, 2014.
DOI : 10.1109/TUFFC.2014.2994

URL : https://hal.archives-ouvertes.fr/hal-01096016

J. Gennisson, T. Deffieux, E. Macé, G. Montaldo, M. Fink et al., Viscoelastic and Anisotropic Mechanical Properties of in vivo Muscle Tissue Assessed by Supersonic Shear Imaging, Ultrasound in Medicine & Biology, vol.36, issue.5, pp.789-801, 2010.
DOI : 10.1016/j.ultrasmedbio.2010.02.013

M. Tanter, J. Bercoff, L. Sandrin, and M. Fink, Ultrafast compound imaging for 2-D motion vector estimation: application to transient elastography, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control, vol.49, issue.10, pp.1363-1374, 2002.
DOI : 10.1109/TUFFC.2002.1041078

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, High-contrast ultrafast imaging of the heart, Communications scientifiques Publications dans des revues internationales à comité de lecture 1, pp.288-301, 2014.
DOI : 10.1109/TUFFC.2014.6722614

URL : https://hal.archives-ouvertes.fr/hal-01057544

C. Papadacci, M. Tanter, M. Pernot, and M. Fink, Ultrasound backscatter tensor imaging (BTI): analysis of the spatial coherence of ultrasonic speckle in anisotropic soft tissues, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol.61, issue.6, pp.986-996, 2014.
DOI : 10.1109/TUFFC.2014.2994

URL : https://hal.archives-ouvertes.fr/hal-01096016

C. Papadacci, M. Tanter, M. Pernot, and M. Fink, Backscatter Tensor Imaging (BTI): Analysis of the spatial coherence of ultrasonic speckle in anisotropic soft tissues, IEEE Trans. Ultrason. Ferroelectr. Freq. Control, Front Cover Image, 2014.
URL : https://hal.archives-ouvertes.fr/hal-01096016

M. Tanter and . Pernot, 3D ultrafast ultrasound imaging in vivo, Phys. Med. Biol, vol.59, issue.19, p.1, 2014.

D. Shcherbakova, C. Papadacci, A. Swillens, A. Caenen, S. De-bock et al., Supersonic shear wave imaging to assess arterial non-linear behavior and anisotropy: proof of principle via ex-vivo testing of the horse aorta, Adv. Mech. Eng, vol.2014, p.272586, 2014.

S. Chatelin, M. Bernal, T. Deffieux, C. Papadacci, P. Flaud et al., Anisotropic polyvinyl alcohol hydrogel phantom for shear wave elastography in fibrous biological soft tissue: a multimodality characterization, Physics in Medicine and Biology, vol.59, issue.22, pp.6923-6940, 2014.
DOI : 10.1088/0031-9155/59/22/6923

C. Papadacci, J. Provost, J. E. Arango, M. Imbault, M. Gennisson et al., 3D Ultrasound Backscatter Tensor Imaging (BTI): analysis of the full spatial coherence on a 2D matrix array probe

C. Papadacci, T. Mirault, B. Dizier, M. Fink, M. Tanter et al., Noninvasive evaluation of aortic stiffness dependence with aortic blood pressure and internal radius by shear wave elastography

J. Jl-gennisson, T. Provost, C. Deffieux, J. E. Papadacci, M. Arango et al., 3D Shear wave imaging

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, Shear Wave Imaging of the heart using a cardiac phased array with coherent spatial compound, 2012 IEEE International Ultrasonics Symposium, pp.2023-2026, 2012.
DOI : 10.1109/ULTSYM.2012.0506

C. Papadacci, M. Pernot, M. Tanter, and M. Fink, Towards backscatter tensor imaging (BTI): Analysis of the spatial coherence of ultrasonic speckle in anisotropic soft tissues, 2013 IEEE International Ultrasonics Symposium (IUS), pp.1208-1211, 2013.
DOI : 10.1109/ULTSYM.2013.0309

D. Shcherbakova, A. Swillens, A. Caenen, S. De-bock, P. Segers et al., Supersonic shear wave imaging to assess arterial anisotropy: Ex-vivo testing of the horse aorta, 2013 IEEE International Ultrasonics Symposium (IUS), pp.1545-1548, 2013.
DOI : 10.1109/ULTSYM.2013.0393

C. Papadacci, M. Pernot, M. Couade, M. Fink, and M. Tanter, Shear Wave Imaging of the heart using a cardiac phased array with coherent spatial compound, 2012 IEEE International Ultrasonics Symposium, 2012.
DOI : 10.1109/ULTSYM.2012.0506

S. Chatelin, C. Papadacci, M. Fink, M. Tanter, J. Gennisson et al., Analytical and numerical simulations of wave propagation using the visco-elastic anisotroic Green's function for cardiac remote ultrasonic elastography, International Tissue Elasticity Conference (ITEC), 2013.

C. Papadacci, M. Pernot, M. Tanter, and M. Fink, Towards backscatter tensor imaging (BTI): Analysis of the spatial coherence of ultrasonic speckle in anisotropic soft tissues, 2013 IEEE International Ultrasonics Symposium (IUS), 2013.
DOI : 10.1109/ULTSYM.2013.0309

D. Shcherbakova, A. Swillens, A. Caenen, S. De-bock, P. Segers et al., Supersonic shear wave imaging to assess arterial anisotropy: Ex-vivo testing of the horse aorta, 2013 IEEE International Ultrasonics Symposium (IUS), 2013.
DOI : 10.1109/ULTSYM.2013.0393

T. Mirault, C. Papadacci, B. Dizier, M. Tanter, X. Jeunemaitre et al., Non invasive and real time evaluation of mice aortic stiffness by ultrafast ultrasound imaging: a new tool for evaluation of preclinical vascular disease models, European Heart Journal, vol.34, issue.suppl 1, p.2527, 2013.
DOI : 10.1093/eurheartj/eht308.P2527

C. Papadacci, M. Pernot, M. Tanter, and M. Fink, Ultrasound Backscatter Tensor Imaging (BTI): A new tool to map the fiber architecture in fibrous soft tissues, th World Congress of Biomechanics, 2014.

C. Papadacci, T. Mirault, B. Dizier, M. Tanter, M. Pernot et al., Non invasive evaluation of aortic stiffness dependence with aortic blood pressure in rat by ultrasound shear wave imaging, th World Congress of Biomechanics, 2014.

C. Papadacci, J. Provost, J. E. Arango, M. Imbault, M. Gennisson et al., 3D Ultrasound Backscatter Tensor Imaging (BTI): analysis of the full spatial coherence on a 2D matrix array probe, IEEE International Ultrasonics symposium, 2014.

J. Jl-gennisson, C. Provost, T. Papadacci, . Deffieux, M. Arango et al., Full 3D ultrafast shear wave imaging, IEEE International Ultrasonics symposium, 2014.

M. Correia, S. Chatelin, C. Papadacci, J. Provost, O. Villemain et al., Ultrafast Harmonic Compounding for cardiac shear wave imaging, IEEE International Ultrasonics symposium, 2014.

J. Provost, C. Papadacci, C. Demene, O. Villemain, J. E. Arango et al., 3-D Ultrafast Doppler Imaging In Vivo, IEEE International Ultrasonics symposium, 2014.

J. Provost, C. Papadacci, O. Villemain, J. E. Arango, M. Imbault et al., 3-D Ultrafast Imaging of the Heart In Vivo, IEEE International Ultrasonics symposium, 2014.