160 5.2.1. The Tool's Features, p.160 ,
Enduit isolant à base de xerogel de silice, 2011. ,
URL : https://hal.archives-ouvertes.fr/hal-00800396
Vacuum Insulation Panels (VIPs) for building construction industry ??? A review of the contemporary developments and future directions, Applied Energy, vol.88, issue.11, pp.3592-602, 2011. ,
DOI : 10.1016/j.apenergy.2011.04.040
Hygrothermal analysis of a stabilized rammed earth test building in the UK. Energy and Buildings, pp.845-852, 2010. ,
Improving thermal performance of building walls by optimizing insulation layer distribution and thickness for same thermal mass, Applied Energy, vol.88, issue.9, pp.3113-3124, 2011. ,
DOI : 10.1016/j.apenergy.2011.02.036
Effect of thermal bridges on transmission loads and thermal resistance of building walls under dynamic conditions, Applied Energy, vol.98, pp.98-584, 2012. ,
DOI : 10.1016/j.apenergy.2012.04.038
Heat Transfer Characteristics and Optimum Insulation Thickness for Cavity Walls, Journal of Building Physics, vol.26, issue.3, pp.285-307, 2003. ,
DOI : 10.1177/109719603027973
Effect of thermal mass on performance of insulated building walls and the concept of energy savings potential, Applied Energy, vol.89, issue.1, pp.430-472, 2012. ,
DOI : 10.1016/j.apenergy.2011.08.009
Validation of a hygrothermal whole building simulation software Proc. of Building Simulation 2011, 12th Conference of International Building Performance Simulation Association, pp.1694-1701, 2011. ,
Investigation of wall's optimum insulation position from maximum time lag and minimum decrement factor point of view, Energy and Buildings, vol.32, issue.2, pp.197-203, 2000. ,
DOI : 10.1016/S0378-7788(00)00044-X
Numerical computation of time lags and decrement factors for different building materials, Building and Environment, vol.41, issue.5, pp.615-620, 2006. ,
DOI : 10.1016/j.buildenv.2005.02.020
Effects of Wall's thermophysical properties on time lag and decrement factor, Energy and Buildings, vol.28, issue.2, pp.159-166, 1998. ,
DOI : 10.1016/S0378-7788(98)00007-3
Different methods for the modelling of thermal bridges into energy simulation programs: Comparisons of accuracy for flat heterogeneous roofs in Italian climates, Applied Energy, vol.97, pp.405-418, 2012. ,
DOI : 10.1016/j.apenergy.2012.01.022
The influence of the external walls thermal inertia on the energy performance of well insulated buildings, Energy and Buildings, vol.41, issue.11, pp.1181-1188, 2009. ,
DOI : 10.1016/j.enbuild.2009.06.005
Integrated building performance evaluation in the early design stages, Building and Environment, vol.27, issue.2, pp.149-161, 1992. ,
DOI : 10.1016/0360-1323(92)90019-L
The prediction of Thermal Sensation from Simple model of Human Physiological Regulatory Response, ASHRAE Trans, vol.83, 1977. ,
Aerogel insulation for building applications: A state-of-the-art review, Energy and Buildings, vol.43, issue.4, pp.43-761, 2011. ,
DOI : 10.1016/j.enbuild.2010.12.012
Transient analysis of an external building cladding, Energy and Buildings, vol.40, issue.7, pp.1273-1277, 2008. ,
DOI : 10.1016/j.enbuild.2007.11.008
Analysis on existent thermal insulating plasters towards innovative applications: Evaluation methodology for a real cost-performance comparison, Energy and Buildings, vol.77, pp.40-47, 2014. ,
DOI : 10.1016/j.enbuild.2014.03.037
Thermal performance of envelope wall/roofs of intermittent air-conditioned rooms, Applied Thermal Engineering, vol.40, pp.1-7, 2012. ,
DOI : 10.1016/j.applthermaleng.2012.01.051
Mathematical Models for Predicting the Thermal Comfort Response of Building Occupants ,
Etude de parois de batiments passifs associant un materiau à changement de phase et une super isolation transparents, 2011. ,
Effective thermal conductivity of divided silica xerogel beds, Journal of Non-Crystalline Solids, vol.350, pp.379-384, 2004. ,
DOI : 10.1016/j.jnoncrysol.2004.08.238
URL : https://hal.archives-ouvertes.fr/hal-00528565
Study of evaporative drying of treated silica gels, Journal of Non-Crystalline Solids, vol.350, pp.230-237, 2004. ,
DOI : 10.1016/j.jnoncrysol.2004.06.043
URL : https://hal.archives-ouvertes.fr/hal-00528594
Toward a positive-net-energy residential building in Serbian conditions, Applied Energy, vol.88, issue.7, pp.2407-2419, 2011. ,
DOI : 10.1016/j.apenergy.2011.01.011
Influence of thermal insulation position in building envelope on the space cooling of high-rise residential buildings in Hong Kong, Energy and Buildings, vol.33, issue.6, pp.569-581, 2001. ,
DOI : 10.1016/S0378-7788(00)00125-0
Optimum insulation thicknesses for building walls with respect to cooling and heating degree-hours in the warmest zone of Turkey, Building and Environment, vol.43, issue.6, pp.1055-1064, 2008. ,
DOI : 10.1016/j.buildenv.2007.02.014
Performance analysis of a solar concrete collector Energy Conversion and Management, pp.1007-1016, 1992. ,
Energy demands and potential savings in European office buildings: Case studies based on EnergyPlus simulations, Energy and Buildings, vol.65, pp.19-28, 2013. ,
DOI : 10.1016/j.enbuild.2013.05.039
Consommation de chauffage : la récupération des apports gratuits Campbell scientific hygrothermal sensor CS215; retrieved from http://s.campbellsci.com/documents, Promoclim E, 1986. ,
The effect of thermal bridges on the thermal comfort of buildings, 4th International Building Physics Conference, 2009. ,
A building thermal bridges sensitivity analysis, Applied Energy, vol.107, pp.229-243, 2013. ,
DOI : 10.1016/j.apenergy.2013.02.045
Analysis of the influence of installation thermal bridges on windows performance: The case of clay block walls, Energy and Buildings, vol.43, issue.6, pp.1435-1442, 2011. ,
DOI : 10.1016/j.enbuild.2011.02.004
Heat Transfer, 2005. ,
DOI : 10.1201/9780849338960.ch97
Réglementation thermique, 2000. ,
Investigation on energy performance of double skin fa??ade in Hong Kong, Energy and Buildings, vol.41, issue.11, pp.11-1135, 2009. ,
DOI : 10.1016/j.enbuild.2009.05.012
ROBESim: A retrofit-oriented building energy simulator based on EnergyPlus, Energy and Buildings, vol.66, pp.88-103, 2013. ,
DOI : 10.1016/j.enbuild.2013.07.020
Agence de l'Environnement et de la Maîtrise de l'Energie (ADEME), 2009. ,
The Estimation of Atmospheric Radiation for Clear and Cloudy Skies, Proceedings 2nd National Passive Solar Conference (AS/ISES), pp.675-678, 1978. ,
Optimum insulation thickness of external walls for energy saving, Applied Thermal Engineering, vol.23, issue.4, pp.473-479, 2003. ,
DOI : 10.1016/S1359-4311(02)00209-0
Toward aerogel based thermal superinsulation in buildings: A comprehensive review, Renewable and Sustainable Energy Reviews, vol.34, pp.273-299, 2014. ,
DOI : 10.1016/j.rser.2014.03.017
Optimizing insulation thickness and analysing environmental impacts of aerogel-based thermal superinsulation in buildings, Energy and Buildings, vol.77, pp.28-39, 2014. ,
DOI : 10.1016/j.enbuild.2014.03.034
Massive Solar-Thermal Collectors: A critical literature review Renewable and Sustainable Energy Reviews, pp.3666-3679, 2012. ,
Energy potential of a Massive Solar-Thermal Collector design in European climates, Solar Energy, vol.93, pp.195-208, 2013. ,
Réduction de modèles thermiques de bâtiments : amélioration des techniques par modélisation des sollicitations météorologiques, Thèse de doctorat, 1997. ,
A CRITICAL REVIEW OF HYGROTHERMAL MODELS USED IN POROUS BUILDING MATERIALS, Journal of Porous Media, vol.13, issue.3, pp.221-234, 2010. ,
DOI : 10.1615/JPorMedia.v13.i3.30
Dexter building shell elements as passive solar collectors; Proceedings of conference on systems simulation and economic analysis for solar heating and cooling, pp.162-164, 1978. ,
Hygrothermal performance of building components and building elements -Assessment of moisture transfer by numerical simulation, 2007. ,
External coupling between building energy simulation and computational fluid dynamics. Thesis (PhD), 2005. ,
Streamlined life cycle assessment of transparent silica aerogel made by supercritical drying, Applied Energy, vol.97, pp.396-404 ,
DOI : 10.1016/j.apenergy.2011.11.047
Solar engineering of thermal processes, 2006. ,
Application of Advanced Glazing and Overhangs in Residential Buildings. Energy Conversion and Management), pp.212-219, 2011. ,
Energy Efficiency Trends in Buildings in the EU: Lessons from the ODYSSEE MURE project, 2012. ,
Thermal bridges in building construction -Heat flows and surface temperatures -Detailed calculations, 2007. ,
A cost curve for greenhouse gas reduction, 2007. ,
Energy and cost evaluation of thermal bridge correction in Mediterranean climate, Energy and Buildings, vol.43, issue.9, pp.2385-2393, 2011. ,
DOI : 10.1016/j.enbuild.2011.05.028
Thermal comfort: analysis and applications in environmental Engineering. United States, 1970. ,
A Standard Predictive Index of Human Response to the Thermal Environment, ASHRAE Trans, vol.92, 1986. ,
An Effective Temperature Scale Based on a Simple Model of Human Physiological Regulatory Response, ASHRAE Trans, vol.70, 1970. ,
Comparison of Energy Performance Rating of Dwellings in Malta Software (Eprdm) with Designbuilder: EnergyPlus Simulation Programme. Thesis: Bachelor of Industrial Engineering, 2011. ,
Dynamical building simulation: A low order model for thermal bridges losses, Energy and Buildings, vol.40, issue.12, pp.2236-2243, 2008. ,
DOI : 10.1016/j.enbuild.2008.07.003
URL : https://hal.archives-ouvertes.fr/hal-00353388
Passive and Low Energy Cooling of Buildings, 1994. ,
Low-order model for the simulation of a building and its heating Building Services Energy Research Technology, 2000. ,
Hygrothermal Performance Assessment of Novel Interior Insulation Solutions ,
Analytical and comparative testing of EnergyPlus using IEA HVAC BESTEST E100???E200 test suite, Energy and Buildings, vol.36, issue.8, pp.855-863, 2004. ,
DOI : 10.1016/j.enbuild.2004.01.025
Performance simulation for better building design, Proceedings of 21st Conference on Passive and Low Energy Architecture, 2004. ,
DOI : 10.1016/j.enbuild.2004.06.004
Free Convective Heat Transfer Across Inclined Air Layers, Journal of Heat Transfer, vol.98, issue.2, p.189, 1976. ,
DOI : 10.1115/1.3450517
Combined effect of tem-perature and humidity on the deterioration process of insulation materials in ETICS, Proceedings of the 5th Symposium on Building Physics in the Nordic Countries, pp.677-684, 1999. ,
Simulating a Nationally Representative Housing Sample Using EnergyPlus. LBNL-4420E, 2011. ,
Feasibility study of using silica aerogel as insulation for buildings, KTH School of Industrial Engineering and Management, 2012. ,
The validity of ISO-PMV for predicting comfort votes in every-day thermal environments, Energy and Buildings, vol.34, issue.6, 2002. ,
DOI : 10.1016/S0378-7788(02)00018-X
A study on the thermal performance of exterior walls covered with a recently patented silica-aerogel-based insulating coating, Building and Environment, vol.81, pp.112-122, 2014. ,
DOI : 10.1016/j.buildenv.2014.06.017
URL : https://hal.archives-ouvertes.fr/hal-01045072
Limiting windows offset thermal bridge losses using a new insulating coating, Applied Energy, vol.123, pp.220-231, 2014. ,
DOI : 10.1016/j.apenergy.2014.02.043
URL : https://hal.archives-ouvertes.fr/hal-00968818
Optimal location and thickness of insulation layers for minimizing building energy consumption, Journal of Building Performance Simulation, vol.24, issue.6, pp.384-398, 2012. ,
DOI : 10.1016/S0378-7788(02)00071-3
Hygrothermal performance of exterior walls covered with aerogel-based insulating rendering, Energy and Buildings, vol.84, pp.241-251, 2014. ,
DOI : 10.1016/j.enbuild.2014.07.039
URL : https://hal.archives-ouvertes.fr/hal-01076592
Transferring the south solar energy to the north facade through embedded water pipes, Energy, vol.78, 2014. ,
DOI : 10.1016/j.energy.2014.10.078
URL : https://hal.archives-ouvertes.fr/hal-01086909
Development of windows based on highly insulating aerogel glazings, Journal of Non-Crystalline Solids, vol.350, pp.351-357, 2004. ,
DOI : 10.1016/j.jnoncrysol.2004.06.047
Thermal performance evaluation of the wall using heat flux time lag and decrement factor, Energy and Buildings, vol.47, pp.369-374, 2012. ,
DOI : 10.1016/j.enbuild.2011.12.010
Assessment of the Risk for Mold Growth in a Wall Retrofitted with Vacuum Insulation Panels, Proceedings of the 9th Nordic Symposium on Building Physics, 2011. ,
In situ Measurements of Facade Retrofitted with Vacuum Insulation Panels, Proceedings of the 10th International Vacuum Insulation Symposium, pp.15-16, 2011. ,
Elément d'enveloppe d'un bâtiment et ensemble comprenant un tel élément. French Patent application, pp.11-581, 2011. ,
The substitution of comfort PMV values by a new experimental operative temperature, Electronic proceedings of Clima, WellBeing Indoors, 2007. ,
Hygrothermal calculations and laboratory tests on timber-framed wall structures, Building and Environment, vol.38, issue.5, pp.689-697, 2003. ,
DOI : 10.1016/S0360-1323(02)00207-X
Comparison of experimental and theoretical results for the transient heat flow through multilayer walls and flat roofs, Energy, vol.33, issue.12, pp.1816-1823, 2008. ,
DOI : 10.1016/j.energy.2008.07.016
Experimental investigation for total equivalent temperature difference (TETD) values of building walls and flat roofs, Energy Conversion and Management, vol.50, issue.11, pp.2818-2825, 2009. ,
DOI : 10.1016/j.enconman.2009.06.027
Retrieved from www, 2014. ,
Aerogel-based thermal superinsulation: an overview, Journal of Sol-Gel Science and Technology, vol.311, issue.2, pp.315-339, 2012. ,
DOI : 10.1007/s10971-012-2792-9
URL : https://hal.archives-ouvertes.fr/hal-00700709
Comparative assessment of internal and external thermal insulation systems for energy efficient retrofitting of residential buildings, Energy and Buildings, vol.64, pp.123-131, 2013. ,
DOI : 10.1016/j.enbuild.2013.04.004
The effect of south wall's outdoor absorption coefficient on time lag, decrement factor and temperature variations, Energy and Buildings, vol.39, issue.9, pp.1011-1018, 2007. ,
DOI : 10.1016/j.enbuild.2006.11.006
The influence of wall orientation and exterior surface solar absorptivity on time lag and decrement factor in the Greek region, Renewable Energy, vol.33, issue.7, pp.1652-1664, 2008. ,
DOI : 10.1016/j.renene.2007.09.008
The influence of wall orientation and exterior surface solar absorptivity on time lag and decrement factor in the Greek region, Renewable Energy, vol.33, issue.7, pp.1652-1664, 2008. ,
DOI : 10.1016/j.renene.2007.09.008
Multi-dimensional heat transfer through complex buildings envelope assemblies in hourly energy simulation programs, Energy and Buildings, pp.34445-54, 2002. ,
Effect of insulation and mass distribution in exterior walls on dynamic thermal performance of whole buildings, Proceedings Thermal Performance of the Exterior Envelopes of Buildings, 1998. ,
Influence of insulation configuration on heating and cooling loads in a continuously used building, Energy and Buildings, vol.34, issue.4, pp.321-331, 2002. ,
DOI : 10.1016/S0378-7788(01)00121-9
Etude experimentale des transferts de chaleur entre un batiment et son environment: conception, realization, instrumentation d'une cellue test, 1985. ,
Simultaneous heat and moisture transport in building components, 1995. ,
Moisture in exposed building components, Proceedings of the international symposium on moisture problems in building wall, pp.258-266, 1995. ,
Drying of brick walls after impregnation, Internationale Zeitschrift für Bauin-standsetzen 2 H.2, S, pp.87-100, 1996. ,
Early history and future prospects of buildings system simulation, Proceeding of Building Simulation, 1999. ,
A Systematic Approach to Hygrothermal Modeling and Compliance With Failure Criteria Using WUFI®, 5th National Conference of IBPSA-USA, 2012. ,
Series of experiment for empirical validation of solar gain modeling in building energy codes ? experimental setup, test cell, characterization, specifications and uncertainty analyses, Building and Environment, pp.41-1784, 2006. ,
Numerical estimation of time lags and decrement factors for wall complexes including Multilayer Thermal Insulation, in two different climatic zones, Applied Energy, vol.92, pp.92-480, 2012. ,
DOI : 10.1016/j.apenergy.2011.10.007
Heat transmission, 1954. ,
USE of the ANOVA approach for sensitive building energy design, Applied Energy, vol.87, issue.10, pp.3073-83, 2010. ,
DOI : 10.1016/j.apenergy.2010.04.001
Thermal performance of building materials and products -Determination of thermal resistance by means of guarded hot plate and heat flow meter methods -Products of high and medium thermal resistance ,
Performance studies on solar concrete collectors, Solar Energy, vol.42, issue.1, pp.45-56, 1989. ,
DOI : 10.1016/0038-092X(89)90129-1
Performance hygrothermique des matériaux et produits pour le bâtiment - Détermination des propriétés de transmission de la vapeur d'eau NF EN ISO 8130-2. Poudres pour revêtement -Partie 2 : détermination de la masse volumique à l'aide d'un pycnomètre à gaz ,
Performance hygrothermique des matériaux et produits pour le bâtiment - Détermination des propriétés de sorption hygroscopique ,
Simple tool to evaluate energy demand and indoor environment in the early stages of building design. Solar Energy, 2005. ,
Optimum location and distribution of insulation layers on building walls with various orientations, Building and Environment, vol.42, issue.8, pp.3051-3059, 2007. ,
DOI : 10.1016/j.buildenv.2006.07.025
The influence of exterior surface solar absortivity on thermal characteristics and optimum insulation thickness, Building and Environment, vol.39, pp.347-355, 2012. ,
Thermal performance and optimum insulation thickness of building walls with different structure materials, Applied Thermal Engineering, vol.31, issue.17-18, pp.3854-3863, 2011. ,
DOI : 10.1016/j.applthermaleng.2011.07.033
Process for the preparation of monolithic silica aerogels. United States Patent, pp.5-795, 1998. ,
URL : https://hal.archives-ouvertes.fr/hal-00617987
Highly insulating aerogel glazing for solar energy usage, Solar Energy, vol.72, issue.1, pp.21-29, 2002. ,
DOI : 10.1016/S0038-092X(01)00086-X
Silica aerogel granulate material for thermal insulation and daylighting, Solar Energy, vol.79, issue.2, pp.79-131, 2005. ,
DOI : 10.1016/j.solener.2004.08.032
Incorporation of thermal inertia in the aim of installing a natural nighttime ventilation system in buildings, Energy and Buildings, vol.29, issue.2, pp.129-133, 1999. ,
DOI : 10.1016/S0378-7788(98)00057-7
Proposition de modèles simplifiés pour l'étude du comportement thermique des bâtiments, 1984. ,
The degree-day method to estimate the residential heating natural gas consumption in Turkey: a case study, Energy, vol.28, issue.9, 2003. ,
DOI : 10.1016/S0360-5442(03)00035-5
Heat and material transfer in outdoor wall surfaces. Thesis dissertation, University of Stuttgart, 1971. ,
Determination of optimum insulation thicknesses of the external walls and roof (ceiling) for Turkey's different degree-day regions, Energy Policy, vol.35, issue.10, pp.35-5151, 2007. ,
DOI : 10.1016/j.enpol.2007.04.037
Silica aerogel: synthesis, properties and characterization, Journal of Materials Processing Technology, 2007. ,
Thermal performance of ground as an inexpensive solar collector and storage system. Energy Conversion and Management, pp.197-204, 1982. ,
Thermo-hygric properties of a newly developed aerogel based insulation rendering for both exterior and interior applications, Energy and Buildings, vol.44, pp.114-117, 2012. ,
A possible connection between thermal comfort and health, paper LBNL 55134, 2004. ,
Building America Special Research Project: High-R Walls Case Study Analysis, Building Science Corporation, 2009. ,
Investigation of time lags and decrement factors for different building outside temperatures, Energy and Buildings, vol.61, pp.61-62, 2013. ,
DOI : 10.1016/j.enbuild.2013.02.003
The impact of thermal bridges on the energy demand of buildings with double brick wall constructions, Energy and Buildings, vol.40, issue.11, pp.2083-2089, 2008. ,
DOI : 10.1016/j.enbuild.2008.06.006
Literature review and research needs to couple building energy and airflow simulation ,
Co-simulation for Performance Prediction of Innovative Integrated Mechanical Energy Systems in Buildings. Thesis (PhD), 2008. ,
Co-simulation of innovative integrated HVAC systems in buildings, Journal of Building Performance Simulation, vol.112, issue.3, pp.209-230, 2009. ,
DOI : 10.1016/S0928-4869(00)00023-9
Model and tool requirements for co-simulation of building performance, Proceedings of Proceedings of the 15th IASTED Int. Conf. on Applied Simulation and Modelling, pp.26-28, 2006. ,
Comparison of co-simulation approaches for building and HVAC/R system simulation, Proceedings of the Building Simulation, pp.1418-1425, 2007. ,
A Round Robin Test for buildings energy performance in Italy, Energy and Buildings, vol.42, issue.10, pp.1862-1877, 2010. ,
DOI : 10.1016/j.enbuild.2010.05.022
Wall heat loss from intermittently conditioned spaces???The dynamic influence of structural and operational parameters, Energy and Buildings, vol.38, issue.8, pp.1022-1031, 2006. ,
DOI : 10.1016/j.enbuild.2005.11.012
Experimental and theoretical investigation of effects of wall???s thermophysical properties on time lag and decrement factor, Energy and Buildings, vol.34, issue.3, pp.273-278, 2002. ,
DOI : 10.1016/S0378-7788(01)00087-1
Vaisala Hygrothermal sensor ; retrieved from http://www.vaisala.fr/fr, 2014. ,
Energy savings in retrofitted dwellings: economically viable? Energy & Building, 2004. ,
Thermal behavior of building wall elements, Journal of Applied Sciences, vol.6, pp.3128-3133, 2006. ,
Thermal Analysis Research Program Reference Manual. NBSSIR 83-2655, National Bureau of Standards, p.21, 1983. ,
DOI : 10.6028/nbs.ir.83-2655
Night ventilation control strategies in office buildings, Solar Energy, vol.83, issue.10, pp.1902-1915, 2009. ,
DOI : 10.1016/j.solener.2009.07.003
A modular building controls virtual test bed for the integration of heterogeneous systems, Proceedings of SimBuild, 3rd National Conference: International Building Performance Simulation Association, 2008. ,
Artificial neural networks for energy analysis of office buildings with daylighting, Applied Energy, vol.87, issue.2, pp.551-557, 2010. ,
DOI : 10.1016/j.apenergy.2009.06.028